- Stock: In Stock
- Model: PEACO-280-2S/4T-3.7G/5.5P
- SKU: PEACO-VFD-537
Available Options
5hp single phase to three phase VFD is a type of motor controller that drives an AC motor by changing the frequency and voltage of its power supply, can be used a phase converter or frequency converter to drive 3 phase AC motors. The single phase input 3 phase output VFD provides full control, running protections and protection functions. Small in size and light weight.
Our VFD are suitable for single phase and split phase input power supply.
Navigation: Motor Controls > Variable Frequency Drives > 1-Phase 220V to 3-Phase 380V VFD > 5 hp (3.7 kW) VFD, 220V 1-Phase to 380V 3-Phase Inverter
Specifications
Basics | Model | PEACO-1-FC280-2S/4T-3.7G/5.5P | |
Rated Capacity | 5 hp (3.7 kW) | ||
Rated Input Current | 27.0A | ||
Rated Output Current | 9.0A | ||
Certification | CE | ||
Warranty | 12 months | ||
Applicable Motor Output | 3.7 kW | ||
Power | Input Rated Voltage* | Single phase AC 220 V (-15%~+20%) and Split voltage |
|
Output Rated Voltage* | Three phase AC 380V (-15%~+15%) |
||
Rated Frequency | 1.0~3200Hz | ||
Robust Design | IGBT current > 2 times of inverter output current, Capacitor > 50uF/A | ||
PCB aging test | 100% test, 50°C, 12 hours. | ||
Finished products aging test | 100% test, 50°C, 24 hours. | ||
Control Feature | Control System | VF Control / Open Sensor Vector Control / Closed loop Vector (PG card - for lift/elevator) | |
Output Frequency Resolution | 0.1Hz | ||
Torque Characteristics | Including the auto-torque, auto-slip compensation, starting torque can be 0.5 Hz/150% (V/f), 1 Hz/150% (SVC),0 Hz/180% (FVC) | ||
Overload Endurance | 150% / 120s, 160% / 60s, 180% / 10s, 200% / 1s | ||
Acc / Dec Time | 0.1~65000s. (can be set individually) | ||
Torque Boost | Automatically torque boost, manually torque boost: 0.1%~30.0% | ||
Stall Prevention Level | 20~200%, setting of Rated Current | ||
Operating Feature | Input / Output Terminals | Keypad | Removable |
Input terminals | 6 multifunctional inputs, one can be work as high speed pulse Input. 3 programmable analog input: AI1, AI2, AI3: 0~10V / 4~20mA. |
||
Output terminals | 2 Groups relay outputs, 1 open collector outputs. 2 Analog outputs, 0~10V / 4~20mA. |
||
Communication Terminals | Build-in standard RS485 communication interface. MODBUS-RTU communication protocol. | ||
Built-in PID | Built-in PID control to easily realize the close loop control of the process parameters (such as pressure, temperature, flow, etc.) | ||
Jog Operation | Jog operation frequency: 0.0Hz~maximum frequency. Jog acceleration/deceleration time: 0.1s~3600.0s. | ||
Other Function | AVR, S-curve, Over-Voltage Stall Prevention, DC Braking, Fault Records, Adjustable Carried Frequency, Starting Frequency Setting of DC Braking, Over-Current Stall Prevention, Momentary Power Loss Restart, Reverse Inhibition, Frequency Limits, Parameter Lock/Reset. | ||
Protection | Over Voltage, Over Current, Under Voltage, Overload, Electronic thermal, Overheating, Self-testing. | ||
Others | Including EMC Filter (C2/C3 Standard) | ||
Cooling | Forced air-cooling | ||
Installation Location | Altitude 1,000 m or below, keep from corrosive gasses, liquid and dust. | ||
Ambient Temperature | -10°C~+40°C (Non-Condensing and not frozen) | ||
Storage Temperature | -20°C~+60°C | ||
Ambient Humidity | Below 90% RH (non-condensing) | ||
Vibration | 9.80665m/s2 (1G) less than 20Hz, 5.88m/s2 (0.6G) 20 to 50Hz | ||
External Accessories* |
Matched optional input EMC filter, output EMC filter, input AC reactor, output AC reactor, energy regenerated reactor, harmonic filter, sine wave filter (excluding VFD price). |
1. * denotes the parameters are optional or customized and please select every parameter in drop-down lists to complete your order.
2. Please contact us for external accessories catalogue and price.
AC Drive Dimension (Unit: mm)
A | H | D | W | B | Φ | Weight |
118 | 185 | 157 | 106 | 175 | Φ4.5 | 2kg |
Control Circuit Diagram for Industrial Motor
Control Circuit Diagram for Lift or Elevator Motor