Brand new 3 hp (2.2 kW) variable frequency drive is also a phase converter that converts 210V/220V 1-phase to 380V/ 415V/ 440V 3-phase. V/F, sensorless vector control are available. 50Hz/60Hz input frequncy and 1Hz~3200Hz output frequency range. Cost-effective AC drive for AC motor speed control.
Our VFD are suitable for single phase and split phase input power supply.
Navigation: Motor Controls > Variable Frequency Drives > 1-Phase 220V to 3-Phase 380V VFD > 3 hp (2.2 kW) VFD, 220V 1-Phase to 380V 3-Phase Inverter
Specifications
Basics | Model | PEACO-1-FC280-2S/4T-2.2G/3.7P | |
Rated Capacity | 3 hp (2.2 kW) | ||
Rated Input Current | 23.0A | ||
Rated Output Current | 5.1A | ||
Certification | CE | ||
Warranty | 12 months | ||
Applicable Motor Output | 2.2 kW | ||
Power | Input Rated Voltage* | Single phase AC 220 V (-15%~+20%) and Split voltage |
|
Output Rated Voltage* | Three phase AC 380V (-15%~+15%) |
||
Rated Frequency | 1.0~3200Hz | ||
Robust Design | IGBT current > 2 times of inverter output current, Capacitor > 50uF/A | ||
PCB aging test | 100% test, 50°C, 12 hours. | ||
Finished products aging test | 100% test, 50°C, 24 hours. | ||
Control Feature | Control System | VF Control / Open Sensor Vector Control / Closed loop Vector (PG card - for lift/elevator) | |
Output Frequency Resolution | 0.1Hz | ||
Torque Characteristics | Including the auto-torque, auto-slip compensation, starting torque can be 0.5 Hz/150% (V/f), 1 Hz/150% (SVC),0 Hz/180% (FVC) | ||
Overload Endurance | 150% / 120s, 160% / 60s, 180% / 10s, 200% / 1s | ||
Acc / Dec Time | 0.1~65000s. (can be set individually) | ||
Torque Boost | Automatically torque boost, manually torque boost: 0.1%~30.0% | ||
Stall Prevention Level | 20~200%, setting of Rated Current | ||
Operating Feature | Input / Output Terminals | Keypad | Removable |
Input terminals | 6 multifunctional inputs, one can be work as high speed pulse Input. 3 programmable analog input: AI1, AI2, AI3: 0~10V / 4~20mA. |
||
Output terminals | 2 Groups relay outputs, 1 open collector outputs. 2 Analog outputs, 0~10V / 4~20mA. |
||
Communication Terminals | Build-in standard RS485 communication interface. MODBUS-RTU communication protocol. | ||
Built-in PID | Built-in PID control to easily realize the close loop control of the process parameters (such as pressure, temperature,flow, etc.) | ||
Jog Operation | Jog operation frequency: 0.0Hz~maximum frequency. Jog acceleration/deceleration time: 0.1s~3600.0s. | ||
Other Function | AVR, S-curve, Over-Voltage Stall Prevention, DC Braking, Fault Records, Adjustable Carried Frequency, Starting Frequency Setting of DC Braking, Over-Current Stall Prevention, Momentary Power Loss Restart, Reverse Inhibition, Frequency Limits, Parameter Lock/Reset. | ||
Protection | Over Voltage, Over Current, Under Voltage, Overload, Electronic thermal, Overheating, Self-testing. | ||
Others | Including EMC Filter (C2/C3 Standard) | ||
Cooling | Forced air-cooling | ||
Installation Location | Altitude 1,000 m or below, keep from corrosive gasses, liquid and dust. | ||
Ambient Temperature | -10°C~+40°C (Non-Condensing and not frozen) | ||
Storage Temperature | -20°C~+60°C | ||
Ambient Humidity | Below 90% RH (non-condensing) | ||
Vibration | 9.80665m/s2 (1G) less than 20Hz, 5.88m/s2 (0.6Gat) 20 to 50Hz | ||
External Accessories* |
Matched optional input EMC filter, output EMC filter, input AC reactor, output AC reactor, energy regenerated reactor, harmonic filter, sine wave filter (excluding VFD price). |
1. * denotes the parameters are optional or customized and please select every parameter in drop-down lists to complete your order.
2. Please contact us for external accessories catalogue and price.
AC Drive Dimension (Unit: mm)
A | H | D | W | B | Φ | Weight |
118 | 185 | 157 | 106 | 175 | Φ4.5 | 2kg |