Menu
Your Cart

335 hp (250 KW) Soft Starter, 220V/380V/480V, 500A

335 hp (250 KW) Soft Starter, 220V/380V/480V, 500A
335 hp (250 KW) Soft Starter, 220V/380V/480V, 500A
335 hp (250 KW) Soft Starter, 220V/380V/480V, 500A
335 hp (250 KW) Soft Starter, 220V/380V/480V, 500A
335 hp (250 KW) Soft Starter, 220V/380V/480V, 500A
  • Stock: In Stock
  • Model: PEACO-ZJR2-32500
  • SKU: PEACO-SS18
$1,864.68
Ex Tax: $1,864.68

Available Options

Free Shipping Worldwide.
By DHL/ FedEx/ UPS.
Lead Time 7-12 Days.
Mail Us for Lead Time of Custom Products.
MOQ 1.
Buy More Save More.
335 hp, three phase 380V soft starter features 500A of high current, three phase 220V, 240V, 400V, 480V, etc. are also available. High efficiency AC motor soft starter to reduce the mechanical stress on the motor and shaft and extend the motor lifespan. Reliable motor soft starter is applicable for mixer, pump, fan, etc.

Soft Starter User Manual : Peaco Support soft starter user manual.pdf

Features

  1. Smart start. The intelligent motor soft starter comes with various startup modes, including limited current startup mode, voltage ramp startup mode, sudden start mode, current ramp startup and voltage current limiting double closed-loop startup.
  2. Multifunctional operation panel. LCD display for soft starter displays parameters intuitively, easy to operate.
  3. High continuity terminals. Reliable soft starter for induction motor features high-conductivity terminals made of quality and thickened material and good electrical conductivity is available.
  4. Powerful cooling. The motor soft starter provides effective heat dissipation protection so as to quickly reduce the operating temperature.
  5. Multiple protections in one machine. Smart motor soft starter is available with overcurrent, overload, overheat, low voltage, high voltage, load short circuit, output phase loss, input phase loss, three-phase unbalance protections.
  6. High and low temperature resistance. The electronic soft starter is made of industrial grade ABS plastics with high impact resistance, high heat resistance, stable and good performance.

Specification

Product Name: Intelligent Motor Soft Starter

Model: PEACO-ZJR2-32500

Capacity: 335 hp (250 kW)

Current: 500A at 380V

Input Voltage*: Three phase 220V, 240V, 380V, 400V, 415V, 440V, 460V, 480V, 690V

Frequency: 50Hz/ 60Hz

Adaptive Motor: Squirrel-cage three-phase asynchronous motor

Starting Times: It is recommended not to exceed 20 times per hour.

Control Mode

1) Operation panel control.

2) Operation panel + external control.

3) External control.

4) External control + COM control.

5) Operation panel + external + COM control.

6) Operation panel + COM control.

7) COM control.

8) No start or stop operation.

Start Mode

1) Current-limiting to start.

2) Voltage ramp to start.

3) Torque control + current-limiting to start.

4) Torque control + voltage ramp to start.

5) Current ramp to start.

6) Voltage current-limiting double closed-loop start.

Stop Mode

1) Soft stop.

2) Free stop.

Protective Function:

1) Open loop protection for external instantaneous stop terminals.

2) Over-heat protection for soft starter.

3) Protection for too long starting time.

4) Input open phase protection.

5) Output open phase protection.

6) Unbalanced three-phase protection.

7) Starting over current protection.

8) Running overload protection.

9) Under voltage protection for power voltage.

10) Overvoltage protection for power voltage.

11) Protection for fault parameter setting of the soft starter.

12) Load short circuit protection.

13) Auto restart or incorrect wiring protection.

14) Incorrect wiring protection of external control stop terminals.

Ambient

Place to be used: Indoor location with good ventilation free from corrosive gas and conductive dust.

Altitude: Below 1000M. It has to increase the soft starter rate power when the altitude is more than 1000M.

Temperature: -30℃~+55℃

Humidity: ≤90% RH (without dew condensation)

Vibration: <0.5G

Structure

Enclosure: IP 20

Cooling: Natural wind cooling.

Certification: CE, ISO9001

Warranty: 12 months

Outline Dimension (W1*H1*D): 290*550*245mm

Installation Dimension(W2*H2*d): 260*480*M8

Weight: 35 kg

Note: This model of soft starter is without bypass, you need to connect external AC contactor. If you want the soft starter with built-in bypass where there is a AC contactor inside, please contact us.

Softer Starter Outline & Installation Dimension (Unit: mm)

Softer Starter Dimension

Soft Start Wiring Diagram

Soft Start Wiring Diagram

Soft Starter Details

  • Simple control panel. The control panel can be removed to clean, easy to operate, real-time data display on LCD screen.
  • Smart mainboard. Soft starter features fast response, multi-functions.
  • Power control transformer. It comes with energy saving, circulating circuit, high quality coils with insulation isolation.
  • Mutual inductor. the mutual inductor makes the soft starter more standard for measuring instruments, protection equipment and automatic control equipment.

335 hp (250 kW) Soft Starter

Soft Starter Applications

The soft starter well suits motor, water pump, mixer, air compressor, conveyor, gravel crusher, etc.

Soft Starter Applications

KNOWLEDGE BASE ---

Precautions for the use of soft starters

1. The installation and maintenance of the soft starter should be carried out by qualified professionals.

2. It is strictly forbidden to use high voltage test equipment (such as a megger) to test the insulation of the soft starter.

3. If the motor is required to run reversibly and a reversing contactor can be installed on the incoming side, but can not be installed on the output terminal of the soft starter.

4. It is not allowed to connect capacitors at the output terminal of the soft starter.

5. Do not install motor soft starter near the heating element.

6. The specifications of the motor should match the ones of soft start.

7. Users should leave enough space to ensure that the cooling air circulates from the bottom to the top of the soft starter.

8. Make sure that no liquid or conductors fallen in the starter.

9. If the ventilation is insufficient, a forced ventilation device should be added though there is a cooling fan installed in the soft starter itself.

Write a review

Note: HTML is not translated!
Bad Good
Captcha