Menu
Your Cart

20 hp (15 KW) Online Soft Starter, 220V/380V/480V/690V

20 hp (15 KW) Online Soft Starter, 220V/380V/480V/690V
20 hp (15 KW) Online Soft Starter, 220V/380V/480V/690V
20 hp (15 KW) Online Soft Starter, 220V/380V/480V/690V
20 hp (15 KW) Online Soft Starter, 220V/380V/480V/690V
20 hp (15 KW) Online Soft Starter, 220V/380V/480V/690V
  • Stock: In Stock
  • Model: PEACO-JR2-S20
  • SKU: PEACO-OSS4
$526.69
Ex Tax: $526.69

Available Options

Free Shipping Worldwide.
By DHL/ FedEx/ UPS.
Lead Time 7-12 Days.
Mail Us for Lead Time of Custom Products.
MOQ 1.
Buy More Save More.
20 hp online soft starter, 15 KW capacity, three phase 220V, 380V, 480V, 690V. With phase failure, three-phase unbalance, short circuit, etc. protections. Low price soft starter used with pumps, compressors, fans to control soft / direct start and soft stop.

Features

  1. The radiator is more than 3 times heavier than that of traditional soft starter, and the heat dissipation area is over 5 times larger than traditional ones, and the soft starter has an axial fan with forced cooling to ensure the long-term stable and reliable operation of the crystal tube.
  2. There is no AC contactor, no contact, no spark in the cabinet, suitable for use in harsh environments such as smoke, powder and dust.
  3. Online soft starter adopts high-performance single-chip microcomputer and advantaged logic control technology, featuring strong anti-interference ability.
  4. Starting parameters can be flexibly set according to different loads to obtain the best current curve and best torque control.
  5. The soft starter provides a smooth and gradual starting process for the motor, reduce the impact of the starting current on the power grid, reduce the vibration and noise of the equipment, extend the service life of the mechanical transmission system and improve the working environment for workers.
  6. The starting current can be adjusted according to the load to reduce the starting loss and produce the best torque with the smallest current.
  7. The soft stop feature greatly prolongs the life of electrical contacts and meets the mechanical needs on different occasions.
  8. There is no phase sequence requirement for the input current.
  9. Soft starter can be set as free and soft stop and the time of soft stop can be adjusted.
  10. With dynamic fault memory function, which is easy to find the cause of the fault.
  11. Delay start mode and interlock control can be programed.
  12. Soft starter is equipped with 4X LCD display, which is easy to modify the parameters and to operate.
  13. The soft starter structure is novel and compact, the performance is reliable and the installation and operation are easy and simple.

Specification

Product Name Online Soft Starter
Model PEACO-JR2-S20
Capacity, Current 20 hp (15KW), 30A at 380V
Communication DB9 interface, male plug, ① is RS485+, ⑥ is RS485-
Input Voltage* Three phase 220V, 240V, 380V, 400V, 440V, 460V, 480V, 690V
Frequency 50Hz/ 60Hz
Adaptive Motor Squirrel-cage three-phase asynchronous motor
Starting Times It is recommended not to exceed 20 times per hour.
Control Mode 1) Operation panel control.
2) Operation panel + external control.
3) External control.
4) External control + COM control.
5) Operation panel + external + COM control.
6) Operation panel + COM control.
7) COM control.
8) No start or stop operation.
Start Mode 1) Current-limiting to start.
2) Voltage ramp to start.
3) Torque control + current-limiting to start.
4) Torque control + voltage ramp to start.
5) Current ramp to start.
6) Voltage current-limiting double closed-loop start.
Stop Mode 1) Soft stop. 2) Free stop.
Protective Function 1) Open loop protection for external instantaneous stop terminals.
2) Over-heat protection for soft starter.
3) Protection for too long starting time.
4) Input open phase protection.
5) Output open phase protection.
6) Unbalanced three-phase protection.
7) Starting over current protection.
8) Running overload protection.
9) Under voltage protection for power voltage.
10) Overvoltage protection for power voltage.
11) Protection for fault parameter setting of the soft starter.
12) Load short circuit protection.
13) Auto restart or incorrect wiring protection.
14) Incorrect wiring protection of external control stop terminals.
Ambient Place to be used Indoor location with good ventilation free from corrosive gas and conductive dust.
Altitude Below 1000M. It has to increase the soft starter rate power when the altitude is more than 1000M.
Temperature -30℃~+55℃
Humidity ≤90%RH without dew condensation.
Vibration <0.5G
Structure Enclosure IP 20
Cooling Natural wind cooling.
Certification CE, ISO9001
Warranty 12 months
Outline Dimension (W1*H1*D) 148*200*310mm
Installation Dimension(W2*H2*d) 85*280*M6
Weight 5 kg
Note: * denotes optional parameters and you can select every parameter in drop-down lists to complete your order.

Softer Starter Outline & Installation Dimension (Unit: mm)

Softer Starter Dimension

KNOWLEDGE BASE ---

Write a review

Note: HTML is not translated!
Bad Good
Captcha