Menu
Your Cart

95A Capacitor Switching Contactor, 1 NO + 2 NC, 400V

95A Capacitor Switching Contactor, 1 NO + 2 NC, 400V
95A Capacitor Switching Contactor, 1 NO + 2 NC, 400V
95A Capacitor Switching Contactor, 1 NO + 2 NC, 400V
95A Capacitor Switching Contactor, 1 NO + 2 NC, 400V
95A Capacitor Switching Contactor, 1 NO + 2 NC, 400V
  • Stock: In Stock
  • Model: PEACO-CI19-95
  • SKU: PEACO-CI19-95
$210.97
Ex Tax: $210.97

Available Options

Free Shipping Worldwide.
By DHL/ FedEx/ UPS.
Lead Time 7-12 Days.
Mail Us for Lead Time of Custom Products.
MOQ 1.
Buy More Save More.

95A capacitor switching contactor is available with auxiliary contact composition 2 NO+ 1 NC and 1 NO + 2 NC for options, 3 pole, 240V, 400V rated operational volatge. Reliable three phase AC contactor reduces current inrush during switching, thus providing less stress for both the contactor and the capacitor. Good contactor for awitching contactor for extending capacitor and contactor life and increasing system reliability.

AC Contactor Specifications

Model: PEACO-CI19-95

Poles description: 3P

Controllable capacitor capacity: 28.8 Kvar (for 240V), 50 Kvar (for 400V)

Rated insulation voltage: 500V

Rated operational volatge: 220V/240V, 380V/400V (Optional)

Conventional thermal current: 95A

Rated working current AC-6b and 400VA: 72.2A (400V)

Prevention capacity on closing surge: 20le

Action condition: pull-in (85%-110%) Us, release (20%-75%) Us

Coil power (start/keep): 220/20 VA

Control supply voltage: 110V, 127V, 220V, 380V

Highest operating frequency (Time/hour): 120

Electrical life: 100, 000 times

Mechanical life: 1,000,000 times

Auxiliary contact composition: 2 NO+ 1 NC (21), 1 NO + 2 NC (12) (Optional)

Auxiliary contact control capacity: AC-15 360VA, DC-13 33W

Weight: 1.5kg

Warranty: 1 year

Application

CJ19 series capacitor switching contactors are widely used in power network of AC 50H or 60Hz, voltage up to 380V for operating or switching low voltage power capacitor control device in low voltage reactive power circuit. The AC contactor is equipped with an inrush current suppressing device, which can effectively reduce the impact of closing surge on the capacitor and suppress the overvoltage when it is off.

Features

1. The AC contactor is equipped with a current-limiting resistor, which can suppress the closing inrush within the allowable range.

2. Capacitor switching contactor features a direct-acting double-breakpoint structure, with flexible action mechanism and compact structure, convenient to check manually and replace contacts.

3. The AC contactor terminals are covered with an insulating cover, which is safe and reliable.

4. The installation can be fastened with screws or it can be fastened on the 35 mm or 75 mm standard installation rail.

Environment

1. Ambient temperature: -5℃~+40℃, the average value should not exceed +35℃ within 24 hours.

2. Altitude: <2000m.

3. Atmospheric conditions: When the temperature reaches 40℃, the relative humidity of atmosphere should be <50%. When at relatively low temperatures, it could have higher relative humidity, such as relative humidity up to 90% at 20℃. Special measures should be taken if there is occurrence of dews due to temperature changes.

4. Class of pollution: Class 3

5. Installation category. Ⅲ

6. Installation conditions: The inclination degree between the installation surface and the vertical surface does not exceed ±5°.

7. Impact shock: AC contactors should be installed and used in the place where there are no strong shakes and impacts.

AC Contactor Wiring Diagram