High voltage dc contactor features 50A high current, rated load voltage 12~1000VDC and DC 12V/24V coil, is sealed by epoxy resin to withstand a variety of harsh environments, widely used in DC fast charging stations, renewable energy storage systems. High performance, high reliable and energy saving.
For more DC contactors and datasheet, please visit here Peaco Support DC contactor catalogue.pdf.
Features
- Optional coil voltage: 12V DC contactor and 24V DC contactor.
- Epoxy sealed. Epoxy resin encapsulated seal structure allows the working in explosive and harmful environment and coils and contacts will not be oxidized and polluted.
- High efficiency coil. The energy-saving coil holds 2~2.3W power, counter electromotive force up to 0V. The standard type DC contactor and energy saving type DC contactor are optional.
- Non-polarity. There is no polarity requirement for contacts and coil connections.
- No electromagnetic counter force. The joint way of the coil is convenient.
- Compact design, low noise.
- Meet CCC, RoHS, CE and ISO9001 conformance requirements.
Applications: High-voltage DC contactors are used in electric control systems such as automotive electric winches, telecommunication equipment, construction machinery, battery trucks, electric forklifts, trains, ships, uninterrupted power supplies, etc.
Specifications
Basic Specification | Model | PEACO-ADH50-S | PEACO-ADH50-E | |
Weight | 230g | 220g | ||
Dimension | 55*42*62mm | 55*50*62mm | ||
Certification | CCC, RoHS, CE and ISO9001 |
|||
Application | Continuous operation | |||
Contact Specification | Contact Arrangement | SPST-1NO Contact | ||
Auxiliary Contact (Optional)* |
1-NO | |||
Contact Resistance | ≤30mΩ (@6V DC 20A) | |||
Rated Load Voltage | 12~1000VDC | |||
Electrical Endurance (Resistance) | 10,000 times (50A 750V DC) | |||
Maximum Switching Power / Current | 160 kW / 500A 320VDC (>1 time) | |||
Protection Grade | IP67 | |||
Rated Load Current | 50A | |||
Mechanical Life | 1,000,000 times | |||
Min. Load | 1A 12VDC | |||
Standard Continuous (Carry) Current (40mm2 Leads) | 50A | |||
Short Time Overload Current (40mm2 at 40℃) | 75A 15min, 100A 3min, 150A 30s | |||
Load Terminal and Center Distance | M5 Internal Thread, 18mm | |||
Coil Specification | Coil Type (Optional)* | Standard Type Voltage | Energy Saving Type Voltage | |
Standard Type Voltage | 12VDC | 24VDC | 12V/24V DC | |
Working Voltage | 9-16V | 8-32V | 8-36V | |
Max. Voltage | 16V | 32V | 36V | |
Action Voltage | ≤9V | ≤18V | 7-8V | |
Release Voltage | ≥1V | ≥2V | 5-6V | |
Coil Resistance±10% | 26Ω | 96Ω | 4.7Ω | |
Min Start Current | 0.46A | 0.25A | 1.5A | |
Transient Inrush Current | / | / | 2.5A (0.1s) | |
Average Holding Current | 0.46A | 0.25A | 0.18A (@ 12V) | |
Steady State Power | 5.5W | 6.0W | 2.0-2.3W | |
Actuation Times | ≤25ms | ≤25ms | ≤20ms | |
Release Time / Bounce Time | ≤10ms / ≤ 5ms | ≤10ms / ≤ 5ms | ≤10ms / ≤ 5ms |
- Insulation Resistance: 1,000MΩ (500VDC) between contacts, between coil and contacts and between shell and contacts.
- Dielectric Withstanding Voltage: 2,500VAC, ≤1mA Between Coil and Contacts and 8,000VAC, ≤1mA between contacts.
- Impact: 196m/s2 (6ms) stability and 490m/s2 (6 ms) strength.
- Vibration: Sine 80Hz~2000Hz (20G Max.)
- IP Grade: IP67
- Mechanical Life: 1,000,000 times
- Electric Endurance (Resistance): 10,000 times (50A 750VDC)
- Humidity: 5~95% RH
- Temperature: -40℃~85℃
DC Contactor Dimensions (unit: mm)
Notes: Sizes of some products are noted without dimensional tolerance. So, consider the tolerance of ±0.3 mm for dimensions less than 10mm, ±0.5 mm for dimensions 10-50mm and ±0.8 mm for dimensions more than 50 mm.