- Stock: In Stock
- Model: PEACO-FC110-2S/4T-2.2G
- SKU: PEACO-STVFD-3
Available Options
3 hp VFD with single phase input 220V-240V AC to three-phase output features vector control and V/f control method, and provide multiple protection to the motor. Lightweight and affordable variable frequency drive for AC motor speed controls in conveyors, fans, pumps, and heavy-duty operation. User manual provided, simple to install and operate.
Our VFDs are suitable for single-phase and split-phase input power supply.
Navigation: Motor Controls > Variable Frequency Drives >1 Phase to 3 Phase VFD > Single Phase to Three Phase VFD, 3 hp (2.2 kW)
Specifications
Basic Features | Model | PEACO-FC110-2S/4T-2.2G |
Code | G: Constant torque, P: Pump motor | |
Rated capacity | 2.2kW | |
Rated input current | 15A | |
Rated output current | 5A | |
Input rated voltage | 220V | |
Input rated frequency | 50/60Hz | |
Output rated voltage | 380V | |
Allowable output voltage range | 320V~460V | |
Output frequency | Vector control: 300 Hz, V/F control: 3200 Hz | |
Adoptable motor type* | Squirrel cage induction motor, asynchronous motor (Contact us for Permanent Magnet Motor) | |
Control Features | Control mode | Open-loop vector control (SVC), Closed-loop vector control (FVC), V/F control |
Input frequency resolution | Digital setting: 0.01 Hz, Analog setting: Maximum frequency*0.025% | |
Carrier frequency | 0.5 kHZ-16kHZ, Automatically adjusted based on load features. | |
Torque control/Steady speed accuracy | ±5%(FVC)/ ±0.5%>(SVC), ±0.02%(FVC) | |
Start-up torque | G-type: 0.5 Hz/150%, 0 Hz/180% (FVC), P type: 0.5Hz (FVC) | |
Overload capacity | G-type: 150% rated current 60s, 180% rated current 3s, P-type: 120% rated current 60s; 180% rated current 3s | |
Ramp mode | Straight-line ramp or S-curve ramp, Four groups of acceleration /deceleration time with the range of 0.0s-6500.0s | |
DC braking | 0.00Hz - maximum output frequency, Braking time: 0.0s - 36.0s Braking action current value: 0.0% - 100.0%. | |
JOG control | JOG frequency range: 0.00Hz-50.00Hz, JOG acceleration / deceleration time: 0.0s-6500.0s | |
Build-in PID | Realizes process-controlled closed-loop control system easily. | |
Automatic voltage adjustment (AVR) | Maintain constant output voltage automatically when the main voltage changes. | |
Individualized Function | Safety self-inspection of power on peripheral equipment | Safety detection of peripheral equipment such as grounding, short circuits, and so on. |
Over-voltage and Over-loss speed control | Automatic limit of current and voltage during operation to prevent frequent over-current and over-voltage tripping | |
Fast current limit | Minimizing overcurrent fault and protecting frequency converter in normal operation | |
Common DC Bus function | Common DC bus functions of multiple frequency converters. | |
Quick key | User-defined shortcut menu | |
MF.K key | Programmable Key: Command channel Switching/forward and reverse running/JOG running function selection | |
Textile swing frequency control | Given the length control function | |
Timing control | Timing control function: setting time range 0h-65535hr | |
Running command sources | Running command sources | Three channels: operation panel, control terminal, and serial communication port. They can be switched over between these sources in various ways. |
Frequency sources | 10 frequency sources, such as digital setting, analog voltage setting, analog current setting, pulse setting, and serial communication port setting. They can be switched over these sources in various ways. | |
Auxiliary frequency command | 10 kinds of auxiliary frequency instructions. It can realize auxiliary frequency fine adjustment and frequency synthesis flexibly. | |
Input terminal | 7-Digital Input terminal, where X5 is compatible with high-speed pulse input. Suitable for PNP or NPN input mode. | |
2-Analog Input terminal 0-10V/0-20 mA. Used as voltage or current input. | ||
Output terminal | 3-Digital output terminals and 2-Relay output terminals. | |
1-High speed output terminal DO, 0 kHZ-100 kHz square wave signal output, It can realize the set frequency output, output frequency, and other physical quantities. | ||
2-Analog output terminal 0-10V/0-20 mA. Used as voltage or current output. | ||
Display and keyboard | LED display | Display monitoring parameters, output frequency, set frequency, bus voltage, etc. |
Keyboard lock and function selection | To realize partial or total lock of keys, define the scope of action of some keys, to prevent mis-operation. | |
Protection function | Short circuit detection, input and output phase loss protection, overcurrent protection, overvoltage protection, under-voltage protection, overheat protection, and overload protection. | |
Brake unit | Build-in brake unit | |
Environment | Installation location | Indoor, free from direct sunlight, dust-free, corrosive gases, combustible gases, oil smoke, vapor, drip or salt, etc. |
Altitude | <1000m | |
Ambient temperature | < 95 % RH, no water droplet condensation | |
Humidity | -10°C~ +40°C (ambient temperature is 40°C-50°C , please de-rate to use) | |
Vibration | <5.9m/s 2 (0.6g) | |
Storage temperature | -20℃~+60℃ | |
IP level | IP20 | |
Pollution grade | PD2 | |
External Accessories* | Matched optional Brake resistance, input EMC filter, output EMC filter, input AC reactor, output AC reactor, energy regenerated reactor, harmonic filter, and sine wave filter (excluding VFD price). |
1. * denotes the parameters are optional or customized and please select every parameter in drop-down lists to complete your order.
2. Please contact us for the external accessories catalog and price.
AC Drive Dimension (Unit: mm)A | H | D | W | B | Φ | Weight |
118 | 185 | 157 | 106 | 175 | Φ4.5 | 2kg |