15 hp (11 kW) VFD with single phase 220-260V input to three phase output for AC motors, multiple protections such as over-load, over-voltage, over-heat, etc. Our VFD supports V/f control mode, open-loop vector control mode, and close-loop vector control mode to control the motor for multiple applications.

Peaco Support VFDs are suitable for single-phase and split-phase input power supply.

Navigation: Motor Controls > Variable Frequency Drives >1 Phase to 3 Phase VFD > 15 hp VFD, Single Phase to Three Phase Converter

Specifications

Basic Features Model PEACO-FC110-2S/4T-11G
Code G: Constant torque, P: Pump motor
Rated capacity 11kW
Rated input current 72A
Rated output current 24A
Input rated voltage 220V 50/60Hz
Input rated frequency 50/60Hz
Output rated voltage 380V
Allowable output voltage range 320V~460V
Output frequency Vector control: 300 Hz, V/F control: 3200 Hz
Adoptable motor type* Squirrel cage induction motor, asynchronous motor (Contact us for Permanent Magnet Motor)
Control Features Control mode Open-loop vector control (SVC), Closed-loop vector control (FVC), V/F control
Input frequency resolution Digital setting: 0.01 Hz, Analog setting: Maximum frequency*0.025%
Carrier frequency 0.5 kHZ-16kHZ, Automatically adjusted based on load features.
Torque control/Steady speed accuracy ±5%(FVC)/ ±0.5%>(SVC), ±0.02%(FVC)
Start-up torque G-type: 0.5 Hz/150%, 0 Hz/180% (FVC), P type: 0.5Hz (FVC)
Overload capacity G-type: 150% rated current 60 s, 180% rated current 3 s, P-type: 120% rated current 60s; 180% rated current 3 s
Ramp mode Straight-line ramp or S-curve ramp, Four groups of acceleration /deceleration time with the range of 0.0s-6500.0s
DC braking 0.00Hz - maximum output frequency, Braking time: 0.0s - 36.0s Braking action current value: 0.0% - 100.0%.
JOG control JOG frequency range: 0.00Hz-50.00Hz, JOG acceleration / deceleration time: 0.0s-6500.0s
Build-in PID Realizes process-controlled closed-loop control system easily.
Automatic voltage adjustment (AVR) Maintain constant output voltage automatically when the main voltage changes.
Individualized Function Safety self-inspection of power on peripheral equipment Safety detection of peripheral equipment such as grounding, short circuits, etc.
Over-voltage and Over-loss speed control Automatic limit of current and voltage during operation to prevent frequent over-current and over-voltage tripping
Fast current limit Minimizing overcurrent fault and protecting frequency converter in normal operation
Common DC Bus function Common DC bus functions of multiple frequency converters.
Quick key User-defined shortcut menu
MF.K key Programmable Key: Command channel Switching/forward and reverse running/JOG running function selection
Textile swing frequency control Given the length control function
Timing control Timing control function: setting time range 0h-65535hr
Running command sources Running command sources Three channels: operation panel, control terminal, and serial communication port. They can be switched over between these sources in various ways.
Frequency sources 10 frequency sources, such as digital setting, analog voltage setting, analog current setting, pulse setting, and serial communication port setting. They can be switched over these sources in various ways.
Auxiliary frequency command 10 kinds of auxiliary frequency instructions. It can realize auxiliary frequency fine adjustment and frequency synthesis flexibly.
Input terminal 7-Digital Input terminal, where X5 is compatible with high-speed pulse input. Suitable for PNP or NPN input mode.
2-Analog Input terminal 0-10V/0-20 mA. To be used as voltage or current input.
Output terminal 3-Digital output terminals and 2-Relay output terminals.
1-High speed output terminal DO, 0 kHZ-100 kHz square wave signal output, It can realize the set frequency, output frequency, and other physical quantities.
2-Analog output terminal 0-10V/0-20 mA. To be used as voltage or current output.
Display and keyboard LED display Display monitoring parameters, output frequency, set frequency, bus voltage, etc.
Keyboard lock and function selection To realize partial or total lock of keys, define the scope of action of some keys, to prevent mis-operation.
Protection function Short circuit detection, input and output phase loss protection, overcurrent protection, overvoltage protection, under-voltage protection, overheat protection, and overload protection.
Brake unit Build-in brake unit
Environment Installation location Indoor, free from direct sunlight, dust-free, corrosive gases, combustible gases, oil smoke, vapor, drip or salt, etc.
Altitude <1000m
Ambient temperature -10°C~ +40°C (ambient temperature is 40°C-50°C , please de-rate to use) 
Humidity <95 % RH, no water droplet condensation
Vibration <5.9m/s 2 (0.6g)
Storage temperature -20℃~+60℃
IP level IP20
Pollution grade PD2
External Accessories* Matched optional Brake resistance, input EMC filter, output EMC filter, input AC reactor, output AC reactor, energy regenerated reactor, harmonic filter, and sine wave filter (excluding VFD price).
Note:

1. * denotes the parameters are optional or customized and please select every parameter in drop-down lists to complete your order.

2. 15-hp single-phase to three-phase VFD comes with a built-in brake unit. The customer must install brake resistance along with VFD when rapid deceleration or brake is activated for the motor.

3. Please contact us for an external accessories catalog and price.

AC Drive Schematic Diagram

AC Drive Schematic Diagram
AC Drive Dimension (Unit: mm)

AC Drive Dimension

AHDWBΦWeight
148247187.5161234.5Φ5.63.6kg

KNOWLEDGE BASE --- Can PLC control an induction motor without VFD?
A programmable logic controller (PLC) or programmable controller is an industrial computer control system designed for application in an industrial environment. The PLC monitors the input device status and controls the output device status according to custom programs. However, A variable frequency drive (VFD) is a motor controller that drives AC induction motors by varying the frequency and voltage of their input power supply. PLC has the function to switch on and off induction motors but cannot control the motor speed. When acceleration or deceleration of the induction motor is desired, VFD is needed for the motor.