- Stock: In Stock
- Model: PEACO-CJX2-32
- SKU: PEACO-ACC-5
Available Options
An AC contactor is an electrical switching device that can switch an electrical circuit on and off. 32 amps AC contactor is one of CJX2 AC contactors, featuring optional contact coil and auxiliary contact, including 24V, 48V, 110V, 220V AC, etc. Cost-effective 3 pole/ 4 pole AC contactors with small volume, light weight, low consumption, good safety.
32A Electrical AC Contactor Specifications
Model | PEACO-CJX2-32 | ||
Rated current* (optional) |
380V | AC-3 | 32A |
AC-4 | 12A | ||
660V | AC-3 | 21A | |
AC-4 | 7.5A | ||
Conventional heating current | 50A | ||
Rated insulation voltage | 690V | ||
Power of controllable 3-phase squirrel cage motor (AC-3) | 220V | 7.5kW | |
380V | 15kW | ||
660V | 18.5kW | ||
Operational frequency | Electric life | AC-3 | 600 operations/h |
AC-4 | 150 operations/h | ||
Mechanical life | 3600 operations/h | ||
Service life | Electric life | AC-3 | 800,000 operations |
AC-4 | 200,000 operations | ||
Mechanical life | 800,000 operations | ||
Matching fusing model | RT16-50 | ||
Average power consumption at 50Hz, 20℃ | Pick-up | 110VA | |
Holding | 11VA | ||
Pole* (Optional) | 3P+NO, 3P+NC | ||
Weight | 0.55kg | ||
Certification | CCC | ||
Warranty | 2 years |
Note: For electricity-related maintenance and installation, make sure that the operator holds the qualification for electrical work and takes necessary power-off and insulation protection measures.
Features
- 32 pieces of iron core with solid materials, the suction is more smooth and tight.
- Provides silver alloy contacts with strong conductivity and flame retardant housing.
- With copper coils with strong electromagnetic suction when the coil is energized.
Normal Working and Installation Conditions
1. Ambient temperature: -5℃~+40℃, the average value should not exceed +35℃ within 24 hours.
2. Altitude: <2000m.
3. Atmospheric conditions: When the temperature reaches 40℃, the relative humidity of atmosphere should be <50%. When at relatively low temperatures, it could have higher relative humidity. Monthly maximum relative humidity could be not more than 90%. Special measures should be taken if there is occurrence of dews due to temperature changes.
4. Class of pollution: Class 3
5. Installation category. Ⅲ
6. Installation conditions: The inclination degree between the installation surface and the vertical surface does not exceed ±5°.
7. Impact shock: AC contactors should be installed and used in the place where there are no strong shakes and impacts.
AC Contactor Dimension (Unit: mm)
Amax=57, Bmax=86, Cmax=100, Dmax=133, Emax=154, Fmax=83, a=40, b=50/60, Φ=4.5