Menu
Your Cart

4 kVA Isolation Transformer, 3 Phase, 480V to 400V

4 kVA Isolation Transformer, 3 Phase, 480V to 400V
4 kVA Isolation Transformer, 3 Phase, 480V to 400V
4 kVA Isolation Transformer, 3 Phase, 480V to 400V
4 kVA Isolation Transformer, 3 Phase, 480V to 400V
4 kVA Isolation Transformer, 3 Phase, 480V to 400V
4 kVA Isolation Transformer, 3 Phase, 480V to 400V
Custom
4 kVA Isolation Transformer, 3 Phase, 480V to 400V
4 kVA Isolation Transformer, 3 Phase, 480V to 400V
4 kVA Isolation Transformer, 3 Phase, 480V to 400V
4 kVA Isolation Transformer, 3 Phase, 480V to 400V
4 kVA Isolation Transformer, 3 Phase, 480V to 400V
4 kVA Isolation Transformer, 3 Phase, 480V to 400V
4 kVA Isolation Transformer, 3 Phase, 480V to 400V
  • Stock: In Stock
  • Model: PEACO-SG-4KVA
  • SKU: PEACO-SG-4KVA
$1,379.68
Ex Tax: $1,379.68

Available Options

Free Shipping Worldwide.
By DHL/ FedEx/ UPS.
Lead Time 7-12 Days.
Mail Us for Lead Time of Custom Products.
MOQ 1.
Buy More Save More.
The 4 kVA isolation transformer is a small isolation transformer, converts three phase 480 Volt to 400 Volt, 400 Volt to 230 Volt and other input/output voltage can be customized. Electrical isolation transformer adopts advanced winding machine and acuum pressure dipping equipment. Dry type isolation transformer with high efficiency, low heat loss, low cost.

Technical Parameters

  • Model : PEACO-SG-4KVA
  • Capacity* : 4 kVA (Customized)
  • Frequency : 50Hz/60Hz
  • Primary voltage (VAC)* : 120V/ 190V/ 208V/ 220V/ 230V/ 240V/ 380V/ 400V/ 440V/ 415V/ 460V/ 480V/690V...(Customized)
  • Secondary voltage (VAC)* : 120V/ 190V/ 208V/ 220V/ 230V/ 240V/ 380V/ 400V/ 440V/ 415V/ 460V/ 480V/690V...(Customized)
  • Withstand voltage test : 100% tested. Primary to secondary 2.5kV AC/min; Primary to safety ground 2.5kV AC/min; Secondary to safety ground 2.5kV AC/min. (does not have both puncture and break-down)
  • Insulation resistance : >100MΩ / DC500V
  • Insulation class : B/H
  • Overload capability : 300% for 10 seconds, 150% for 120 seconds
  • Efficiency : ≥98%
  • Short circuit impedance : 4%
  • Total Harmonic Distortion : ≤1%
  • Power factor : 0.8
  • Primary to secondary winding isolation voltage : 1000V~3000V
  • Connection mode : standard Dyn11 and customized Ynyn0, Yd11, Dd0. Dyn5. Dzn0, etc, as per customer requriements.
  • Temperature rise limit : 100K (actual temperature minus ambient temperature)
  • Enclosure protection grade : standard IP22 indoor ( contact us for customized electrostatic shield or IP54, IP65 outdoor).
  • Cooling mode : Natural cooling / fan system cooling
  • Display* : Analogue display, digital display.

Transformer Material

  • Material: Transformer coil adopts 200 degree high temperature copper or aluminum wire.
  • Winding material* : 100% copper or aluminum (Optional)

Working Environment

  • Noise : ≤45dB (within 1m)
  • Environment temperature : -20℃~+50℃, indoor enclosure, floor-mounted

Quality Assurance

  • Standard : IEC60076-1, VDE0550, IEC439, JB5555, GB5226, etc.
  • Certification : CE, RoHS and ISO:9001
  • Design Life : 30 years
  • Warranty : 1 year
Note: * denotes optional and customized parameters and you can select every parameter in drop-down lists to complete your order. Please tell us your needed connection type.
Features and Benefits
The small isolation transformer is a 1 to 1 isolation transformer. Peaco Support provides custom isolation transformer with special input and output voltages. For example, 240V to 240V isolation transformer, 440V to 230V step down transformer, 380V to 460V step up transformer, etc can be also customized. The three phase isolation transformers in Peaco Support have the following features and benefits:
  1. Silicon Steel Sheet: New cold rolled silicon steel sheet, 0.27mm, 0.30mm, 0.35mm of thickness, excellent performance.
  2. Terminal Block: High quality terminal block, excellent temperature resistance, pressure resistance and flame retardancy for small power. For high power, made of quality copper material, with good electrical conductivity, high temperature resistance, not easy to burn out the equipment when short circuit happens.
  3. Enameled Wires: H class enamelled copper/aluminum wires, temperature resistance 200℃, winded tightly and uniformly, no insulating layer, high heat dissipation, service life ≥35 years.
  4. Bobbin: The 3 phase isolation transformer is made of nylon, high temperature resistance, great flame retardancy. The high power transformer with frameless design has ventilation slots between the coils for smooth air flows which reduce temperature of coils.
  5. Insulation Process: The whole transformer adopts H-class vacuum impregnated insulation, temperature resistance of 200°C, lower noise, better insulation and is anti-rust and anti-corrosion.
3 Phase Isolation Transformer
Isolation Transformer Dimension (Unit:mm)
Types Dimension Weight
Open Type (A*B*C) Mounting Size (D*E) Enclosed Type (A*B*C) Open Type Enclosed Type
Aluminium Wire Transformer 300*155*310mm 180*125mm 300*440*500mm 40kg 52kg
Copper Wire Transformer 300*155*310mm 180*125mm 300*440*500mm 40kg 52kg
3 Phase Isolation Transformer Dimension
Isolation Transformer Schematic Diagram
3 Phase Isolation Transformer Schematic Diagram
KNOWLEDGE BASE --- Isolation Transformer Functions
Isolation transformer works as general circuit control power, safety lighting and indicator lights in the electronic industry or industrial and mining enterprises, machine tools and mechanical equipment.
  • The main function of isolation transformer is to completely insulate the electricity on the primary side and secondary side and also to isolate the circuit.
  • In addition, the high-frequency loss of its iron core is used to prevent high-frequency clutter from entering the control loop.
  • Isolation transformer makes the secondary suspend to the ground only in the occasions with a small power supply range and short lines. At this time, the capacitance current of the system to ground is too small to cause personal injury.
  • The last function is that isolation transformer protects personal safety and isolate dangerous voltages.
In general, isolation transformer provides galvanic isolation and is used to protect against electric shock, to suppress electrical noise in sensitive devices and to transfer power between two circuits which must not be connected together.