Menu
Your Cart

500VA Control Transformer, 1 Phase, 240V/480V to 120V

500VA Control Transformer, 1 Phase, 240V/480V to 120V
500VA Control Transformer, 1 Phase, 240V/480V to 120V
500VA Control Transformer, 1 Phase, 240V/480V to 120V
500VA Control Transformer, 1 Phase, 240V/480V to 120V
500VA Control Transformer, 1 Phase, 240V/480V to 120V
500VA Control Transformer, 1 Phase, 240V/480V to 120V
500VA Control Transformer, 1 Phase, 240V/480V to 120V
Custom
500VA Control Transformer, 1 Phase, 240V/480V to 120V
500VA Control Transformer, 1 Phase, 240V/480V to 120V
500VA Control Transformer, 1 Phase, 240V/480V to 120V
500VA Control Transformer, 1 Phase, 240V/480V to 120V
500VA Control Transformer, 1 Phase, 240V/480V to 120V
500VA Control Transformer, 1 Phase, 240V/480V to 120V
500VA Control Transformer, 1 Phase, 240V/480V to 120V
500VA Control Transformer, 1 Phase, 240V/480V to 120V
  • Stock: In Stock
  • Model: PBK-500VA
  • SKU: PBK-500VA
$384.68
Ex Tax: $384.68

Available Options

Free Shipping Worldwide.
By DHL/ FedEx/ UPS.
Lead Time 7-12 Days.
Mail Us for Lead Time of Custom Products.
MOQ 1.
Buy More Save More.
500VA control transformer with 240/480 VAC primary / 120 VAC secondary, 1 phase, 50/60 Hz, open type, max. working efficiency 99%, provides durable construction. This single phase transformer can be used as small power supplies.
Specification
Model PBK-500VA
Winding Material* Enameled copper wire or enameled aluminum wire (Optional)
Capacity* 500VA (Customized)
Primary Voltage (VAC)* 110, 120, 208, 220, 230, 240, 380, 400, 440, 460, 480, 110/220, 120/240, 240/480, 600...(Customized)
Secondary Voltage (VAC)* 6, 12, 24, 36, 48, 110/48, 120/24, 208/36, 220/48, 230/36, 240/120, 120/24/12, 110/36/24, 127/36/6, 208/48/36/24...(Customized)
Withstand Voltage Test Primary to secondary 2.5KV/min; Primary to safety ground 2.5KV/min; Secondary to safety ground 1.5KV/min.
Insulation Resistance Primary to secondary 2500V>100 megohm; Primary to safety ground 2500V>100 megohm; Secondary to safety ground 1500V>100 megohm.
Frequency* 50 / 60Hz Insulation Level F / H
Induction Withstand Voltage Test 125Hz/ 800V/min Ground Resistance 25<A80 milliohm
Cooling Method Natural or air cooling Transformation Ratio <3%
Air Carrying Current <6% Impedance Voltage About 6%
Total Losses / Efficiency 0.1 / 80%~99% Operating Temperature -25℃~40℃ (40℃, 93% RH, 56 days)
Noise ≤35~65dB (A)(within 1 metre) Storage Temperature -25℃~100℃ (40℃, 93% RH, 56 days)
Certificate CE, ISO Designed Life 30 years
Warranty 1 year Net Weight 8 kg
Overall Size (A*B*C) 132*140*150mm Installation Dimension (D*E) 100*110mm
Note: * denotes optional and customized parameters and you can select every parameter in drop-down lists to complete your order.
Control Transformer Features
  • Terminal Block: High quality terminal block, excellent temperature resistance, pressure resistance and flame retardancy.
  • Silicon Steel Sheet: New cold rolled silicon steel sheet, 0.27mm, 0.30mm, 0.35mm, excellent performance.
  • Enameled Wires: H class, temperature resistance180℃, winded tightly and uniformly, no insulating layer, high heat dissipation, service life ≥35 years.
  • Bobbin: Made of nylon, high temperature resistance, great flame retardancy, has ventilation slots between the coils for smooth air flows and reducing temperature of coils.
  • Insulation Process: Vacuum impregnated insulation, temperature resistance of 180°C, lower noise, better insulation and is anti-rust and anti-corrosion.

The single phase control transformers are widely used in CNC machine tools and mechanical equipment, working lighting and signal lamp power supplies and can also be used as small power supplies.

Single Phase Control Transformer
Control Transformer Dimension & Schematic Diagram
Control Transformer DimensionControl Transformer Schematic Diagram
KNOWLEDGE BASE --- Transformer Introduction?
  • Transformer Principle
A transformer is an instrument that transforms magnetic power into an electrical power and a device that changes AC voltage based on the electromagnetic induction principle.
  • Transformer Sections
The main components of a transformer are magnetic iron core (magnetic section), primary winding and secondary winding (electrical sections). Its primary winding receives power, while the secondary section delivers energy. A magnet iron circuit introduced as the core is usually used to wrap these parts. Whereas these two primary and secondary coils are isolated electrically and are linked magnetically.
  • Transformer Working Principle
Once current passes through the primary windings of the transformer, a magnetic field is generated, which generates a voltage in the secondary windings of the transformer. According to the type of application, single phase transformers are used to reduce or increase (step down or step up) the output voltage. This type of transformer is usually a power transformer with high efficiency and less waste.
  • Transformer Function
The main functions of transformers are to convert voltage, convert current, convert impedance, isolate and stabilize voltage, etc.

Write a review

Note: HTML is not translated!
Bad Good
Captcha