Menu
Your Cart

25 kVA Isolation Transformer, 3 Phase, 440V to 220V

25 kVA Isolation Transformer, 3 Phase, 440V to 220V
25 kVA Isolation Transformer, 3 Phase, 440V to 220V
25 kVA Isolation Transformer, 3 Phase, 440V to 220V
25 kVA Isolation Transformer, 3 Phase, 440V to 220V
25 kVA Isolation Transformer, 3 Phase, 440V to 220V
25 kVA Isolation Transformer, 3 Phase, 440V to 220V
25 kVA Isolation Transformer, 3 Phase, 440V to 220V
25 kVA Isolation Transformer, 3 Phase, 440V to 220V
25 kVA Isolation Transformer, 3 Phase, 440V to 220V
25 kVA Isolation Transformer, 3 Phase, 440V to 220V
25 kVA Isolation Transformer, 3 Phase, 440V to 220V
25 kVA Isolation Transformer, 3 Phase, 440V to 220V
25 kVA Isolation Transformer, 3 Phase, 440V to 220V
  • Stock: In Stock
  • Model: PEACO-SG-25KVA
  • SKU: PEACO-SG-25KVA
$4,449.97
Ex Tax: $4,449.97

Available Options

Free Shipping Worldwide.
By DHL/ FedEx/ UPS.
Lead Time 7-12 Days.
Mail Us for Lead Time of Custom Products.
MOQ 1.
Buy More Save More.

25 kVA isolation transformer is a three phase isolation transformer with 440V primary voltage and 220V secondary voltage, providing galvanic isolation between the AC power lines (mains) and the powered device. Dry type isolation transformer with H class enamelled wires (copper/aluminum winding), temperature resistance 200℃, great anti-harmonic interference function. Low 3 phase isolation transformer price and high efficiency ≥98%. Custom isolation transformers are also available.

Technical Parameters

  • Model : PEACO-SG-25KVA
  • Capacity* : 25 kVA (Customized)
  • Frequency : 50Hz/60Hz
  • Primary voltage (VAC)* : 120V/ 190V/ 208V/ 220V/ 230V/ 240V/ 380V/ 400V/ 440V/ 415V/ 460V/ 480V/690V...(Customized)
  • Secondary voltage (VAC)* : 120V/ 190V/ 208V/ 220V/ 230V/ 240V/ 380V/ 400V/ 440V/ 415V/ 460V/ 480V/690V...(Customized)
  • Withstand voltage test : 100% tested. Primary to secondary 2.5kV AC/min; Primary to safety ground 2.5kV AC/min; Secondary to safety ground 2.5kV AC/min. (does not have both puncture and break-down)
  • Insulation resistance : >100MΩ / DC500V
  • Insulation class : B/H
  • Overload capability : 300% for 10 seconds, 150% for 120 seconds
  • Efficiency : ≥98%
  • Short circuit impedance : 4%
  • Total Harmonic Distortion : ≤1%
  • Power factor : 0.8
  • Primary to secondary winding isolation voltage : 1000V~3000V
  • Connection type*: standard Dyn11 and customized Ynyn0, Yd11, Dd0. Dyn5. Dzn0, etc, as per customer requriements.
  • Temperature rise limit : 100K (actual temperature minus ambient temperature)
  • Enclosure protection grade : standard IP22 indoor ( contact us for customized electrostatic shield or IP54, IP65 outdoor).
  • Cooling mode : Natural cooling / fan system cooling
  • Display* : Analogue Display, digital display.

Transformer Material

  • Material*: Transformer coil adopts 200 degree high temperature copper or aluminum wire.
  • Winding material : 100% copper or aluminum (Optional)

Working Environment

  • Noise : ≤45dB (within 1m)
  • Environment temperature : -20℃~+50℃, indoor enclosure, floor-mounted

Quality Assurance

  • Standard : IEC60076-1, VDE0550, IEC439, JB5555, GB5226, etc.
  • Certification : CE, RoHS and ISO:9001
  • Design Life : 30 years
  • Warranty : 1 year
Note: * denotes optional and customized parameters and you can select every parameter in drop-down lists to complete your order.
Features and Benefits
  1. Isolation transformers prevent transmission of the DC component in signals from one circuit to the other, but allow AC components in signals to pass. Such an isolation ransformer provides a ratio of 1 to 1 between the primary and secondary windings, is widely used to protect secondary circuits and individuals from electrical shocks between energized conductors and earth ground.
  2. Additionally, the 1 to 1 isolation transformer has the function of anti-harmonic interference caused by ground loops and comes with electrostatic shields so that such transformers are used for power supplies for sensitive equipment, such as computers, medical equipment, audio equipment, robot devices or laboratory instruments.
  3. We provide custom isolation transformer with special input and output voltages. For example, 240V to 240V isolation transformer, 440V to 230V step down transformer, 380V to 460V step up transformer, etc can be also customized. The three phase isolation transformers in Peaco Support have the following features and benefits:
  • Silicon Steel Sheet

New cold rolled silicon steel sheet, 0.27mm, 0.30mm, 0.35mm of thickness, excellent performance.

  • Terminal Block

High quality terminal block, excellent temperature resistance, pressure resistance and flame retardancy for small power. For high power, made of quality copper material, with good electrical conductivity, high temperature resistance, not easy to burn out the equipment when short circuit happens.

  • Enameled Wires

H class enamelled copper or aluminum wires for options, temperature resistance 200℃, winded tightly and uniformly, no insulating layer, high heat dissipation, service life ≥35 years.

  • Bobbin

The bobbin of isolation transformer is made of nylon, high temperature resistance, great flame retardancy. The high power transformer with frameless design has ventilation slots between the coils for smooth air flows which reduce temperature of coils.

  • Insulation Process

The 25 kVA isolation transformer adopts H-class vacuum impregnated insulation, temperature resistance of 200°C, lower noise, better insulation and is anti-rust and anti-corrosion.

3 Phase Isolation Transformer
Isolation Transformer Details

25 kVA Isolation Transformer Dimension (Unit:mm)
Types Dimension Weight
Open Type (A*B*C) Mounting Size (D*E) Enclosed Type (A*B*C) Open Type Enclosed Type
Aluminium Wire Transformer 440*330*430mm 300*185mm 420*610*610mm 140kg 165kg
Copper Wire Transformer 440*330*420mm 300*185mm 420*610*610mm 142kg 168kg
3 Phase Isolation Transformer Dimension
Isolation Transformer Schematic Diagram
3 Phase Isolation Transformer Schematic Diagram

Write a review

Note: HTML is not translated!
Bad Good
Captcha