- Stock: In Stock
- Model: PEACO-AZJ600
- SKU: PEACO-AZJ600
Available Options
600A DC contactor is an electrical switching device designed to switch current on and off. High-current 12V dc contactor, 24V dc coil contactor, and 48v dc contactor provide continuous working duty, 1NO or 1NC single pole contact arrangement, 12V-60V dc contact voltage, and optional high-quality auxiliary contact. Better conductivity, longer service life, and high-temperature resistance, suitable for various electric vehicles.
For a datasheet of the DC contactor, please visit here Peaco Support DC contactor catalogue.pdf.
Applications
The 600 Amps DC contactors feature continuous working duty, 1NO or 1NC contact and are used in electric vehicles, hybrid electric vehicles, fuel cell cars, construction machinery, photovoltaic power generation, wind power, battery charging, and discharging system. Peaco Support 600A dc contactor 12V, dc contactor 24V, and dc contactor 48V are supplied to the USA, Canada, South America, Europe, Africa, Asia, Australia, and New Zealand.
Specification
Physical Performance | Model | PEACO-ZJ600 |
Dimension | 130*80*117mm (Max.) | |
Weight | 1510g | |
Warranty | 1 year | |
Certification | CE, RoHS, ISo9001 | |
Operating Environment | Altitude | ≤ 2km |
Ambient Temperature | -25℃~+80℃ | |
Protection Grade | IP20 | |
Installation Category | III | |
Installation Way | Side | |
Vibration | 2.5G (5Hz-50Hz) | |
Impact | 50g, 11ms (Half-sine Wave) | |
Technical Parameters | Load Terminal and Center Distance | M12 External Thread/105mm |
Coil Type | Single / Dual Coil | |
Coil Rated Voltage* | 12V/24V/36V/48V/60V DC | |
Contact Circuit Rated Load Current | 600A | |
Main Contact Voltage Drop at 600A Load | ≤80mV | |
The Cooling Pull-in Voltage at (20±5)℃ | ≤70%Us | |
The Cooling Pull-out Voltage at (20±5)℃ | ≥5%Us, ≤40%Us | |
The Allowed Range of Coil Voltage | ±20% | |
Pull-in Time (N/O Contacts to Close) | ≤50ms | |
Pull-out Time (N/C Contacts to Open) | ≤30ms | |
Contact Opening Maximum Bounce Period | ≤5ms | |
Insulation Resistance | ≥50MΩ | |
Dielectric Withstanding Voltage | 50Hz/60Hz 1500V AC/1min | |
Overload Current | ≤ 7le, ≤ 1s | |
Coil Power (Single Coil Type) | ≤ 12W | |
Coil Power (Dual Coil and 1 NC Type) | Start ≤ 75W, Hold ≤ 7W | |
Electric Life (Resistive) | 20,000 times (600A 48V DC) | |
Mechanical Life | 200,000 times | |
Operation Duty | Continuous | |
Contact Form* | SPST-NO or SPST-NC | |
Contact Material | AgSnO/Cu or AgCuO/Cu | |
Technical Specification | GB14048.4-2010 | |
Auxiliary Contact Form (Optional)* |
MS-micro switch |
|
Auxiliary Contact Rated Load |
2A/48VDC, 5A/24VDC |
Note: * denotes optional or customized parameters and you can select every parameter in drop-down lists to complete your order.
600A DC Contactor Installation Diagram (Unit: mm)
600A DC Contactor Wiring Diagram