12V 20.8A AC-DC Switching Power Supply 250W
- Stock: In Stock
- Model: PEACO-S-250-12
- SKU: PEACO-SMPS-250-12
$175.67
Ex Tax: $175.67
Free Shipping Worldwide.
By DHL/ FedEx/ UPS.
Lead Time 7-12 Days.
Mail Us for Lead Time of Custom Products.
MOQ 1.
Buy More Save More.
High performance AC-DC switching power supply converts 90~132V AC / 180~264V AC to 12V DC at the power of 250W and 20.8A rated current. Good price SMPS power supply with full functions, stable output, strong anti-interference can be used for industrial monitoring.
Features
- AC input range can be selectable with switch.
- AC to DC switching power supply comes with short circuit, overload, over voltage, under voltage, over temperature protections.
- Switching power supply featues built-in fan for rapid cooling, 100% full load burn-in test for reliable use.
- Fixed switching frequency is at 25KHz.
- Low cost, high reliability. 6 years warranty, CE certified.
12V SMPS Power Supply Specification
Model | PEACO-S-250-12 | |
Output | DC Voltage | 12V |
Rated Current | 20.8A | |
Current Range | 0~20.8A | |
Rated Power | 250W | |
Ripple & Noise (Max.) | <150mV | |
Voltage Adjustment Range | ±10% |
|
Voltage Tolerance | ±1.0% |
|
Line Regulation | ±0.5% | |
Load Regulation | <±0.5% | |
Setup, Rise, Hold Time | 200ms, 50ms, 20ms : 220V AC | |
Input | Voltage Range | 90~132V AC / 180~264V AC |
Frequency Range | 47~63Hz, 254~370V DC | |
Efficiency | >82% | |
AC Current | <4A 115V AC, 2.5A 230V AC | |
Inrush Current | 25A 115V AC, 50A 220V AC | |
Leakage Current | Input - output: 1.5kVA<5mA, Input - output: 220V AC<1mA | |
Protection | Over Load | ≥ 105%~135%, Protection type : Constant current output + VO drop to undervoltage point cut off output reset: power up again |
Over Voltage | ≥ 115%~135% VOUT | |
Under voltage | ≤ 35%~45% VOUT | |
Short Circuit | + VO drops to undervoltage point to close output | |
Over Temperature | RTH3: ≥ 60℃ fan start, ≤ 50℃, ≥80℃ close the output (5V), RTH3: ≥ 65℃ fan start, ≤ 55℃ fan closed, ≥ 85℃ close the output (12V~48V) | |
Environment | Working Temperature | -10 ~ +50℃ |
Working Humidity | 20 ~ 90% RH non-condensing | |
Storage Temperature & Humidity | -20 ~ +85℃, 10 ~ 95% RH | |
Temperature Coefficient | +0.03%/℃ (0~50℃) | |
Vibration | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | |
Safety | Safety Standard | TUV EN60950-1, EN60335-1, EN61558-1/-2-16, UL60950-1, GB494 |
Withstand Volatge | I/P-O/P: 1.5KVAC, I/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC last for 1 min. | |
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500V DC | |
Others | Dimension | 215*114*50mm (L*W*H) |
N.W. / G.W. | 866g/925g | |
Note | 1. All parameters are measured at 230V AC input, rated load and 25℃ of ambient temperature if they are NOT specially mentioned. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance includes set up tolerance, line regulation and load regulation. 4. Linear adjustment rate test: testing from low vóltage to high voltage at rated load load. 5. Load adjustment rate test: from 0%-100% rated load. 6. The start-up time is measured in the cold start state and the fast and frequent booting and shutting down may increase the startup time. 7. When the altitude is above 2000 meters, the operating temperature should be lowered by 5℃/1000m. |
AC-DC Switching Power Details
Switching Power Supply Diagram