![Variable Area Flowmeter, LCD Vertical Thread Connection Variable Area Flowmeter, LCD Vertical Thread Connection](https://peacosupport.com/image/cache/catalog/flowmeters/flowmeter-e-550x550.jpg)
- Stock: In Stock
- Model: PEACO-LZDH-5
- SKU: PEACO-FL-5
Available Options
Competitive price variable area flowmeter is supplied by Peaco Support, featuring vertical thread connection mode, M9 indicator header with pointer indicating instantaneous flow, LCD displaying instantaneous flow and cumulative total volume, +4~20mA remote transmission and HART communication, widely used in energy, medicine, light industry, food, water treatment and other industrial fields.
Features
1. The functions of M9 intelligent indicators: pointer for on-site indication +4~20mA remote transmission, liquid crystal display (simultaneous display of instantaneous and cumulative flow), HART communication.
2. The metal tube variable area flowmeter is applicable for flow measurement of medium with small diameter and low flow velocity.
3. There are low requirements for front and rear straight pipe sections.
4. Two displays are optional: the pointer indicating the instantaneous flow, the LCD displaying the instantaneous flow and the cumulative total.
5. The float flowmeter adopts all metal structure, is suitable for high temperature, high pressure and strong corrosive medium
6. The flowmeter can be used in inflammable and explosive dangerous occasion.
7. The variable area flowmeter comes with the functions of data backup and power failure protection (LCD type).
8. High quality flowmeter features reliable operation, less maintenance and long service life.
9. Wide range ratio 10:1 is available.
10. There are multi parameter calibration, keyboard setting alarm (with alarm type).
11. There are optional external power supply or self-contained 3.6V lithium battery power supply.
Technical Parameter
PEACO-LZDH series of metal tube float flowmeter features microprocessor MCU microprocessor, magnetic sensor, the digital filtering, digital signal processing technology including software correction to test the magnetic field changes and provides a good human-computer interaction interface through liquid crystal display screen, 4-20 mA current output signal, the upper and lower limit alarm, etc. LCD display shows both instantaneous flow and accumulated flow, providing users with more convenience. The variable area flowmeter is widely used in national defense, chemical industry, petroleum, metallurgy, energy, medicine, light industry, food, water treatment and other industrial departments of flow detection and process control.
Model | PEACO-LZDH-5 (The pointer indicating instantaneous flow.) |
Measuring range | Liquid (20℃) 2.5-160000L/h, Gas (20°C, 0.101325MPa) 0.07-4000m3/h |
Range ratio | Standard type 10:1 |
Pressure rating | Standard type: DN15mm-DN50mm 4.0MPa, DN80mm-DN150mm, 1.6MPa |
Pressure loss | 2kPa-20kPa |
Medium viscosity | DN15mm: η<5mPa.s |
DN25mm: η<250PFa.s | |
DN50mm-DN150mm: η<300mPa.s | |
Indicator for liquid crystal display | Instantaneous flow display numerical range:0-60000 |
The cumulative flow display numerical range: 0-99999999x5 | |
Indicator conversion accuracy | Instantaneous value: 0.5%FS±Lmsd |
Cumulative value: 0.5%FS±Lmsd | |
Liquid crystal temperature | -10℃-+85℃ |
Influence of temperature | 0.5%/10℃ |
Guard time | Data power-off protection period of 10 years |
Power supply mode | Two-wire system, DC24V |
Load resistance | 4~20mA 0~600Ω |
Power consumption | 25 mW |
Alarm mode | Solid state relay, current 200mA, voltage 50V, regardless of AC and DC power supply interface and the other part of the isolation. |
Explosion proof mark: Intrinsically safe | iaIICTS |
With the security grid model | FB906 |
Cable interface | M201x.5 |
Protection grade | IP65 |
The implementation of product standards | JB/T6844-93 JJG257-2007 |
Flange connection |
Flange connection standard HG20592-2010 |
Threaded connection* |
According to the diameter or according to customer requirements. |
Hygienic clamp connection | According to the diameter or according to customer requirements. |
Note: Please tell us caliber, measuring medium, medium density, operating temperature, operating pressure, flow range, installation form (vertical or horizontal) when you are ordering.
Flow Range
Nominal Diameter | Flow range | Pressure loss | |||||
Liquid | Gas | Kong Banxing | Cone tube | ||||
Conventional type | Anticcorrosion type | Water | Air | Water | Air | ||
DN15mm | 2.5-25L/h 4.0-40L/h 6.3-63L/h 10-100L/h 16-160L/h 25-250L/h 40-400L/h 63-630L/h |
/ 2.5-25L/h 4.0-40L/h 6.3-63L/h 10-100L/h 16-160L/h 25-250L/h 40-400L/h |
0.07-7Nm3/h 0.11-1.1Nm3/h 0.18-1.8Nm3/h 0.28-2.8Nm3/h 0.48-4.8Nm3/h 0.7-7.0Nm3/h 1.0-10.0Nm3/h 1.6-16.0Nm3/h |
5.5 5.5 5.5 5.6 5.6 5.8 6.0 7.3 |
7.1 7.2 7.3 7.5 8.0 9.8 10.0 14.0 |
2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 |
2.6 2.6 2.6 2.6 2.6 2.6 2.8 3.2 |
DN20mm | 63-630L/h 80-800L/h 100-1000L/h |
40-400L/h 63-630L/h 80-800L/h |
1.6-16.0Nm3/h 2.4-24.0Nm3/h 3.6-36.0Nm3/h |
5.8 5.9 7.0 7.4 |
8.2 9.3 12.5 13.0 |
2.2 2.2 2.2 2.3 |
2.4 2.6 2.8 3.0 |
DN25mm | 63-630L/h 100-1000L/h 160-1600L/h 250-2500L/h 400-4000L/h |
40-400L/h 63-630L/h 100-1000L/h 160-1600L/h 250-2500L/h |
1.6-16.0Nm3/h 3.0-30.0Nm3/h 4.5-45.0Nm3/h 7.0-70.0Nm3/h 11.0-110.0Nm3/h |
5.7 5.9 6.0 6.8 9.2 |
7.2 7.7 8.8 12.0 19.0 |
2.4 2.4 2.5 2.6 3.0 |
3.2 3.3 3.4 3.8 4.5 |
DN32mm | 500-5000L/h 800-8000L/h 1000-10000L/h |
400-4000L/h 500-5000L/h 800-8000L/h |
14.0-140.0Nm3/h 23.0-230.0Nm3/h 35.0-350.0Nm3/h |
5.9 6.8 10.0 |
7.5 8.8 11.0 |
2.6 2.6 2.9 |
4.5 4.8 5.1 |
DN40mm | 630-6300L/h 1000-10000L/h 1200-12000L/h |
400-4000L/h 630-6300L/h 1000-10000L/h |
18.0-180.0Nm3/h 25.0-250.0Nm3/h 40.0-400.0Nm3/h |
6.0 7.2 12.0 |
7.8 9.5 12.0 |
3.0 3.3 3.6 |
4.9 5.2 6.8 |
DN50mm | 630-6300L/h 1000-10000L/h 1600-16000L/h |
400-4000L/h 630-6300L/h 1000-10000L/h |
18.0-180.0Nm3/h 25.0-250.0Nm3/h 40.0-400.0Nm3/h |
6.8 9.4 14.5 |
8.6 10.4 15.5 |
3.3 3.8 4.3 |
7.4 7.7 8.4 |
DN65mm | 1600-16000L/h 2000-20000L/h 2500-25000L/h |
1000-10000L/h 1600-16000L/h 2000-20000L/h |
40.0-400.0Nm3/h 65.0-650.0Nm3/h 100.0-1000.0Nm3/h |
6.8 10.0 12.8 |
9.5 13.8 17.5 |
3.4 3.4 3.5 |
7.5 8.1 9.4 |
DN80mm | 2500-25000L/h 4000-40000L/h |
1600-16000L/h 2500-25000L/h |
70.0-700.0Nm3/h 100.0-1000.0Nm3/h |
6.9 8.0 |
12.9 18.5 |
3.6 4.6 |
6.9 8.9 |
DN100mm | 6300-63000L/h 10000-100000L/h |
4000-40000L/h 6300-630000L/h |
160.0-1600.0Nm3/h 250.0-2500.0Nm3/h |
8.5 8.8 |
19.2 19.6 |
5.8 6.4 |
12.0 12.8 |
DN125mm | 12000-120000L/h | 10000-100000L/h | 300.0-3000.0Nm3/h | 9.0 | 20.3 | 7.0 | 13.5 |
DN150mm | 16000-160000L/h | 12000-120000L/h | 400.0-4000.0Nm3/h | 9.2 | 20.8 | 7.1 | 13.8 |
ZH | The pointer indicating instantaneous flow. | Display form | ||||||||||
DH | The pointer indicating the instantaneous flow with signal output. | |||||||||||
DN15mm-DN 150mm | Nominal diameter | |||||||||||
Lower-upper (not standard) | Structure form | |||||||||||
H1 | Left into, right out | |||||||||||
H2 | Right into, left out | |||||||||||
AA | Side into, side out | |||||||||||
LA | Bottom side | |||||||||||
N | Flange connection (not standard) | Connection mode | ||||||||||
L | Thread connection | |||||||||||
W | Hygienic clamp connection | |||||||||||
RR4 | 304 1Cr18Ni9Ti | Measuring tube material | ||||||||||
RR6 | 316L 00Cr17Ni14Mo2 | |||||||||||
RR6L | 316 0Cr18Ni12Mo2Ti | |||||||||||
HC4 | Hastelloy C alloy | |||||||||||
Ti | Titanium alloy | |||||||||||
F | 304 lining PTFE | |||||||||||
M7 | Square indicator, the pointer indicates instantaneous flow. | Indicator type | ||||||||||
M9 | Square indicator with liquid crystal display. | |||||||||||
M10 | Circular (explosion) indicator, the pointer indicates instantaneous flow. | |||||||||||
M12 | Circular (explosion) indicator with liquid crystal display. | |||||||||||
N | No output (not standard) | |||||||||||
ESK | 4-20mA current output | |||||||||||
EX | 4-20mA current output, intrinsically safe explosion-proof type | |||||||||||
H | With HART protocol | |||||||||||
K1 | With upper limit alarm | |||||||||||
K2 | With lower limit alarm | |||||||||||
K12 | With alarm | |||||||||||
D | DC24V two-wire system | |||||||||||
L | 3.6V lithium battery | |||||||||||
T | With insulation jacket. | Additional features | ||||||||||
HT | The temperature is higher than 120℃. | |||||||||||
Q | Gas | Measuring medium | ||||||||||
Y | Liquid | |||||||||||
DH | DN25MM | RR4 | M7 | ESK | D | Q | (example) |