Menu
Your Cart

Variable Area Flowmeter, Vertical Thread Connection

Variable Area Flowmeter, Vertical Thread Connection
Variable Area Flowmeter, Vertical Thread Connection
  • Stock: In Stock
  • Model: PEACO-LZZH-2
  • SKU: PEACO-FL-2
$375.67
Ex Tax: $375.67

Available Options

Free Shipping Worldwide.
By DHL/ FedEx/ UPS.
Lead Time 7-12 Days.
Mail Us for Lead Time of Custom Products.
MOQ 1.
Buy More Save More.

The variable area flowmeter comes with a square pointer indicator, vertical thread connection can be produced according to the diameter and customer requirements. Nominal diameter up to DN15mm-DN150mm with no output and with 4-20mA output to choose. The metal tube variable area flowmeter adopts metal structure, suitable for high temperature, high pressure and strong corrosive medium.

Features

1. M7 pointer indicates 4-20mA remote transmission and mechanical upper and lower limit alarm (adjustable alarm point) functions. M7 pointer local indication + mechanical upper and lower limit alarm (alarm point is adjustable), the upper limit alarm setting range is 50-100%, the lower limit alarm setting range is 0-50%, and the alarm hysteresis setting range is 0-5% , When the relay output is connected to the FB889 safety grid, an intrinsic safety explosion-proof system can be formed.

2. The metal tube variable area flowmeter is applicable for flow measurement of medium with small diameter and low flow velocity.

3. There are low requirements for front and rear straight pipe sections.

4. Two displays are optional: the pointer indicating the instantaneous flow, the LCD displaying the instantaneous flow and the cumulative total (LCD type).

5. The float flowmeter adopts all metal structure, is suitable for high temperature, high pressure and strong corrosive medium

6. The flowmeter can be used in inflammable and explosive dangerous occasion.

7. The variable area flowmeter comes with the functions of data backup and power failure protection (LCD type).

8. High quality flowmeter features reliable operation, less maintenance and long service life.

9. Wide range ratio 10:1 is available.

10. There are multi parameter calibration, keyboard setting alarm (with alarm type).

11. There are optional external power supply or self-contained 3.6V lithium battery power supply.

Technical Parameter

PEACO-LZZH series of metal tube rotameter is a common area of flow measuring instrument in the industrial automation process control, featuring small size, stable and reliable operation, suitable for measuring of liquid, gas for the measurement of various flow in various environments.

Model PEACO-LZZH-2 (The pointer indicating instantaneous flow.)
Measuring range Liquid (20℃) 2.5-160000L/h, Gas (20°C, 0.101325MPa) 0.07-4000m3/h
Range ratio Standard type 10:1
Pressure rating Standard type: DN15mm-DN50mm 4.0MPa, DN80mm-DN150mm, 1.6MPa
Pressure loss 2kPa-20kPa
Medium viscosity DN15mm: η<5mPa.s
DN25mm: η<250PFa.s
DN50mm-DN150mm: η<300mPa.s
Indicator for liquid crystal display Instantaneous flow display numerical range:0-60000
The cumulative flow display numerical range: 0-99999999x5
Indicator conversion accuracy Instantaneous value: 0.5%FS±Lmsd
Cumulative value: 0.5%FS±Lmsd
Liquid crystal temperature -10℃-+85℃
Influence of temperature 0.5%/10℃
Guard time Data power-off protection period of 10 years
Power supply mode Two-wire system, DC24V
Load resistance 4~20mA 0~600Ω
Power consumption 25 mW
Alarm mode Solid state relay, current 200mA, voltage 50V, regardless of AC and DC power supply interface and the other part of the isolation.
Explosion proof mark: Intrinsically safe iaIICTS
With the security grid model FB906
Cable interface M201x.5
Protection grade IP65
The implementation of product standards JB/T6844-93 JJG257-2007
Flange connection
Flange connection standard HG20592-2010
Threaded connection*
According to the diameter or according to customer requirements.
Hygienic clamp connection According to the diameter or according to customer requirements.

Note: Please tell us caliber, measuring medium, medium density, operating temperature, operating pressure, flow range, installation form (vertical or horizontal) when you are ordering.

Flow Range

Nominal Diameter Flow range Pressure loss
Liquid Gas Kong Banxing Cone tube
Conventional type Anticcorrosion type Water Air Water Air
DN15mm
2.5-25L/h
4.0-40L/h
6.3-63L/h
10-100L/h
16-160L/h
25-250L/h
40-400L/h
63-630L/h
/
2.5-25L/h
4.0-40L/h
6.3-63L/h
10-100L/h
16-160L/h
25-250L/h
40-400L/h
0.07-7Nm3/h
0.11-1.1Nm3/h
0.18-1.8Nm3/h
0.28-2.8Nm3/h
0.48-4.8Nm3/h
0.7-7.0Nm3/h
1.0-10.0Nm3/h
1.6-16.0Nm3/h
5.5
5.5
5.5
5.6
5.6
5.8
6.0
7.3
7.1
7.2
7.3
7.5
8.0
9.8
10.0
14.0
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.6
2.6
2.6
2.6
2.6
2.6
2.8
3.2
DN20mm
63-630L/h
80-800L/h
100-1000L/h
40-400L/h
63-630L/h
80-800L/h
1.6-16.0Nm3/h
2.4-24.0Nm3/h
3.6-36.0Nm3/h
5.8
5.9
7.0
7.4
8.2
9.3
12.5
13.0
2.2
2.2
2.2
2.3
2.4
2.6
2.8
3.0
DN25mm
63-630L/h
100-1000L/h
160-1600L/h
250-2500L/h
400-4000L/h
40-400L/h
63-630L/h
100-1000L/h
160-1600L/h
250-2500L/h
1.6-16.0Nm3/h
3.0-30.0Nm3/h
4.5-45.0Nm3/h
7.0-70.0Nm3/h
11.0-110.0Nm3/h
5.7
5.9
6.0
6.8
9.2
7.2
7.7
8.8
12.0
19.0
2.4
2.4
2.5
2.6
3.0
3.2
3.3
3.4
3.8
4.5
DN32mm
500-5000L/h
800-8000L/h
1000-10000L/h
400-4000L/h
500-5000L/h
800-8000L/h
14.0-140.0Nm3/h
23.0-230.0Nm3/h
35.0-350.0Nm3/h
5.9
6.8
10.0
7.5
8.8
11.0
2.6
2.6
2.9
4.5
4.8
5.1
DN40mm
630-6300L/h
1000-10000L/h
1200-12000L/h
400-4000L/h
630-6300L/h
1000-10000L/h
18.0-180.0Nm3/h
25.0-250.0Nm3/h
40.0-400.0Nm3/h
6.0
7.2
12.0
7.8
9.5
12.0
3.0
3.3
3.6
4.9
5.2
6.8
DN50mm
630-6300L/h
1000-10000L/h
1600-16000L/h
400-4000L/h
630-6300L/h
1000-10000L/h
18.0-180.0Nm3/h
25.0-250.0Nm3/h
40.0-400.0Nm3/h
6.8
9.4
14.5
8.6
10.4
15.5
3.3
3.8
4.3
7.4
7.7
8.4
DN65mm
1600-16000L/h
2000-20000L/h
2500-25000L/h
1000-10000L/h
1600-16000L/h
2000-20000L/h
40.0-400.0Nm3/h
65.0-650.0Nm3/h
100.0-1000.0Nm3/h
6.8
10.0
12.8
9.5
13.8
17.5
3.4
3.4
3.5
7.5
8.1
9.4
DN80mm
2500-25000L/h
4000-40000L/h
1600-16000L/h
2500-25000L/h
70.0-700.0Nm3/h
100.0-1000.0Nm3/h
6.9
8.0
12.9
18.5
3.6
4.6
6.9
8.9
DN100mm
6300-63000L/h
10000-100000L/h
4000-40000L/h
6300-630000L/h
160.0-1600.0Nm3/h
250.0-2500.0Nm3/h
8.5
8.8
19.2
19.6
5.8
6.4
12.0
12.8
DN125mm 12000-120000L/h 10000-100000L/h 300.0-3000.0Nm3/h 9.0 20.3 7.0 13.5
DN150mm 16000-160000L/h 12000-120000L/h 400.0-4000.0Nm3/h 9.2 20.8 7.1 13.8
Selection Map
ZH The pointer indicating instantaneous flow. Display form
DH The pointer indicating the instantaneous flow with signal output.
DN15mm-DN 150mm Nominal diameter
Lower-upper (not standard) Structure form
H1 Left into, right out
H2 Right into, left out
AA Side into, side out
LA Bottom side
N Flange connection (not standard) Connection mode
L Thread connection
W Hygienic clamp connection
RR4 304 1Cr18Ni9Ti Measuring tube material
RR6 316L 00Cr17Ni14Mo2
RR6L 316 0Cr18Ni12Mo2Ti
HC4 Hastelloy C alloy
Ti Titanium alloy
F 304 lining PTFE
M7 Square indicator, the pointer indicates instantaneous flow. Indicator type
M9 Square indicator with liquid crystal display.
M10 Circular (explosion) indicator, the pointer indicates instantaneous flow.
M12 Circular (explosion) indicator with liquid crystal display.
N No output (not standard)
ESK 4-20mA current output
EX 4-20mA current output, intrinsically safe explosion-proof type
H With HART protocol
K1 With upper limit alarm
K2 With lower limit alarm
K12 With alarm
D DC24V two-wire system
L 3.6V lithium battery
T With insulation jacket. Additional features
HT The temperature is higher than 120℃.
Q Gas Measuring medium
Y Liquid
DH DN25MM RR4 M7 ESK D Q (example)

For more flowmeters to choose, please contact us.

Variable Area Flowmeter
Variable Area Flowmeter

KNOWLEDGE BASE --- Working Principle of Variable Area Flowmeter

The measured medium flows through the float of the measuring tube from bottom to top and the upper and lower ends generate differential pressure to form a lift force. When the lift force received by the float is greater than the weight of the float immersed in the fluid, the float will rise, and the area of the annular gap will increase accordingly. The fluid flow rate drops rapidly, the differential pressure at the upper and lower ends of the float decreases, and the lifting force acting on the float decreases with it. When the lifting force is balanced with the weight of the float immersed in the fluid, the float is stable at a certain position, corresponding to the size of the measured medium flow. The float has a built-in magnetic steel. When the float moves up and down with the medium, the magnetic field changes with the movement of the float.

As for the common type of variable area flowmeter, the follow-up magnet in the local indicator is coupled with the magnet in the float to rotate, and at the same time drive the pointer to indicate the flow rate at this time through the dial.

On the other hand, for the intelligent type, the follow-up magnet in the intelligent indicator is coupled with the magnet in the float, and rotates, and drives the sensor magnet and pointer at the same time, and converts the magnetic field change into an electrical signal through a magnetic sensor. After conversion, digital filtering, temperature compensation, microprocessor processing, D/A output, LCD liquid crystal display will show the instantaneous flow and cumulative flow.