The variable area flowmeter is equipped with a square M7 pointer indicator and M12 explosion-proof indicator indicating instantaneous flow, vertical hygienic clamp connection. Accuracy up to 2.5% F.S for gas and 1.5% F.S for liquid. A wide selection of nominal diameter DN15mm-DN150mm with no output and with 4-20mA output. High performance metal tube variable area flow meter with competitive price and free shipping.

Features

1. M7, M12 pointer indicates 4-20mA remote transmission and mechanical upper and lower limit alarm (adjustable alarm point) functions. M7 pointer local indication + mechanical upper and lower limit alarm (alarm point is adjustable), the upper limit alarm setting range is 50-100%, the lower limit alarm setting range is 0-50%, and the alarm hysteresis setting range is 0-5% , When the relay output is connected to the FB889 safety grid, an intrinsic safety explosion-proof system can be formed.

2. The metal tube variable area flowmeter is applicable for flow measurement of medium with small diameter and low flow velocity.

3. There are low requirements for front and rear straight pipe sections.

4. Two displays are optional: the pointer indicating the instantaneous flow, the LCD displaying the instantaneous flow and the cumulative total (LCD type).

5. The float flowmeter adopts all metal structure, is suitable for high temperature, high pressure and strong corrosive medium

6. The flowmeter can be used in inflammable and explosive dangerous occasion.

7. The variable area flowmeter comes with the functions of data backup and power failure protection (LCD type).

8. High quality flowmeter features reliable operation, less maintenance and long service life.

9. Wide range ratio 10:1 is available.

10. There are multi parameter calibration, keyboard setting alarm (with alarm type).

11. There are optional external power supply or self-contained 3.6V lithium battery power supply.

Technical Parameter

PEACO-LZZH series of metal tube rotameter is a common area of flow measuring instrument in the industrial automation process control, featuring small size, stable and reliable operation, suitable for measuring of liquid, gas for the measurement of various flow in various environments.

Model PEACO-LZZH-3 (The pointer indicating instantaneous flow.)
Measuring range Liquid (20℃) 2.5-160000L/h, Gas (20°C, 0.101325MPa) 0.07-4000m3/h
Range ratio Standard type 10:1
Pressure rating Standard type: DN15mm-DN50mm 4.0MPa, DN80mm-DN150mm, 1.6MPa
Pressure loss 2kPa-20kPa
Medium viscosity DN15mm: η<5mPa.s
DN25mm: η<250PFa.s
DN50mm-DN150mm: η<300mPa.s
Indicator for liquid crystal display Instantaneous flow display numerical range:0-60000
The cumulative flow display numerical range: 0-99999999x5
Indicator conversion accuracy Instantaneous value: 0.5%FS±Lmsd
Cumulative value: 0.5%FS±Lmsd
Liquid crystal temperature -10℃-+85℃
Influence of temperature 0.5%/10℃
Guard time Data power-off protection period of 10 years
Power supply mode Two-wire system, DC24V
Load resistance 4~20mA 0~600Ω
Power consumption 25 mW
Alarm mode Solid state relay, current 200mA, voltage 50V, regardless of AC and DC power supply interface and the other part of the isolation.
Explosion proof mark: Intrinsically safe iaIICTS
With the security grid model FB906
Cable interface M201x.5
Protection grade IP65
The implementation of product standards JB/T6844-93 JJG257-2007
Flange connection
Flange connection standard HG20592-2010
Threaded connection
According to the diameter or according to customer requirements.
Hygienic clamp connection* According to the diameter or according to customer requirements.

Note: Please tell us caliber, measuring medium, medium density, operating temperature, operating pressure, flow range, installation form (vertical or horizontal) when you are ordering.

Flow Range

Nominal Diameter Flow range Pressure loss
Liquid Gas Kong Banxing Cone tube
Conventional type Anticcorrosion type Water Air Water Air
DN15mm
2.5-25L/h
4.0-40L/h
6.3-63L/h
10-100L/h
16-160L/h
25-250L/h
40-400L/h
63-630L/h
/
2.5-25L/h
4.0-40L/h
6.3-63L/h
10-100L/h
16-160L/h
25-250L/h
40-400L/h
0.07-7Nm3/h
0.11-1.1Nm3/h
0.18-1.8Nm3/h
0.28-2.8Nm3/h
0.48-4.8Nm3/h
0.7-7.0Nm3/h
1.0-10.0Nm3/h
1.6-16.0Nm3/h
5.5
5.5
5.5
5.6
5.6
5.8
6.0
7.3
7.1
7.2
7.3
7.5
8.0
9.8
10.0
14.0
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.6
2.6
2.6
2.6
2.6
2.6
2.8
3.2
DN20mm
63-630L/h
80-800L/h
100-1000L/h
40-400L/h
63-630L/h
80-800L/h
1.6-16.0Nm3/h
2.4-24.0Nm3/h
3.6-36.0Nm3/h
5.8
5.9
7.0
7.4
8.2
9.3
12.5
13.0
2.2
2.2
2.2
2.3
2.4
2.6
2.8
3.0
DN25mm
63-630L/h
100-1000L/h
160-1600L/h
250-2500L/h
400-4000L/h
40-400L/h
63-630L/h
100-1000L/h
160-1600L/h
250-2500L/h
1.6-16.0Nm3/h
3.0-30.0Nm3/h
4.5-45.0Nm3/h
7.0-70.0Nm3/h
11.0-110.0Nm3/h
5.7
5.9
6.0
6.8
9.2
7.2
7.7
8.8
12.0
19.0
2.4
2.4
2.5
2.6
3.0
3.2
3.3
3.4
3.8
4.5
DN32mm
500-5000L/h
800-8000L/h
1000-10000L/h
400-4000L/h
500-5000L/h
800-8000L/h
14.0-140.0Nm3/h
23.0-230.0Nm3/h
35.0-350.0Nm3/h
5.9
6.8
10.0
7.5
8.8
11.0
2.6
2.6
2.9
4.5
4.8
5.1
DN40mm
630-6300L/h
1000-10000L/h
1200-12000L/h
400-4000L/h
630-6300L/h
1000-10000L/h
18.0-180.0Nm3/h
25.0-250.0Nm3/h
40.0-400.0Nm3/h
6.0
7.2
12.0
7.8
9.5
12.0
3.0
3.3
3.6
4.9
5.2
6.8
DN50mm
630-6300L/h
1000-10000L/h
1600-16000L/h
400-4000L/h
630-6300L/h
1000-10000L/h
18.0-180.0Nm3/h
25.0-250.0Nm3/h
40.0-400.0Nm3/h
6.8
9.4
14.5
8.6
10.4
15.5
3.3
3.8
4.3
7.4
7.7
8.4
DN65mm
1600-16000L/h
2000-20000L/h
2500-25000L/h
1000-10000L/h
1600-16000L/h
2000-20000L/h
40.0-400.0Nm3/h
65.0-650.0Nm3/h
100.0-1000.0Nm3/h
6.8
10.0
12.8
9.5
13.8
17.5
3.4
3.4
3.5
7.5
8.1
9.4
DN80mm
2500-25000L/h
4000-40000L/h
1600-16000L/h
2500-25000L/h
70.0-700.0Nm3/h
100.0-1000.0Nm3/h
6.9
8.0
12.9
18.5
3.6
4.6
6.9
8.9
DN100mm
6300-63000L/h
10000-100000L/h
4000-40000L/h
6300-630000L/h
160.0-1600.0Nm3/h
250.0-2500.0Nm3/h
8.5
8.8
19.2
19.6
5.8
6.4
12.0
12.8
DN125mm 12000-120000L/h 10000-100000L/h 300.0-3000.0Nm3/h 9.0 20.3 7.0 13.5
DN150mm 16000-160000L/h 12000-120000L/h 400.0-4000.0Nm3/h 9.2 20.8 7.1 13.8
Selection Map
ZH The pointer indicating instantaneous flow. Display form
DH The pointer indicating the instantaneous flow with signal output.
DN15mm-DN 150mm Nominal diameter
Lower-upper (not standard) Structure form
H1 Left into, right out
H2 Right into, left out
AA Side into, side out
LA Bottom side
N Flange connection (not standard) Connection mode
L Thread connection
W Hygienic clamp connection
RR4 304 1Cr18Ni9Ti Measuring tube material
RR6 316L 00Cr17Ni14Mo2
RR6L 316 0Cr18Ni12Mo2Ti
HC4 Hastelloy C alloy
Ti Titanium alloy
F 304 lining PTFE
M7 Square indicator, the pointer indicates instantaneous flow. Indicator type
M9 Square indicator with liquid crystal display.
M10 Circular (explosion) indicator, the pointer indicates instantaneous flow.
M12 Circular (explosion) indicator with liquid crystal display.
N No output (not standard)
ESK 4-20mA current output
EX 4-20mA current output, intrinsically safe explosion-proof type
H With HART protocol
K1 With upper limit alarm
K2 With lower limit alarm
K12 With alarm
D DC24V two-wire system
L 3.6V lithium battery
T With insulation jacket. Additional features
HT The temperature is higher than 120℃.
Q Gas Measuring medium
Y Liquid
DH DN25MM RR4 M7 ESK D Q (example)

For more flowmeters to choose, please contact us.

Variable Area Flowmeter

Variable Area Flowmeter

KNOWLEDGE BASE --- Installation Instructions

1. The metal tube float flowmeter must be mounted vertically on the non-vibration pipeline. The fluid flows through the flowmeter from bottom to top and the verticality is ≤ 2° and the horizontal angle is ≤ 2° when installed horizontally.

2. In order to facilitate the maintenance and replacement of flow meters as well as cleaning of measuring pipelines, metal tube float flowmeters installed in process pipelines should be equipped with bypass pipelines and bypass valves.

3. The inlet of the metal tube float flowmeter should adopt a straight pipe section of more than 5 times the diameter of the tube and the outlet should have a straight pipe section of 250 mm.

4. If the medium contains ferromagnetic substances, flocs or solid impurities, magnetic filters should be installed.

5. When used for gas measurement, the pressure loss of pipeline should be not less than 5 times that of flowmeter so as to make the float work steadily.

6. In order to avoid the deformation of flowmeter caused by pipeline, the flange of process pipeline must be coaxial and parallel to the flange of flowmeter. Pipeline support should avoid pipeline vibration and reduce the axial load of flowmeter. The control valve in measurement system should be installed downstream of flowmeter.

7. When measuring gas, if the gas discharges directly into the atmosphere at the outlet of the flowmeter, the valve should be installed at the outlet of the instrument, otherwise the pressure drop will be produced at the float and the data will be not true.

8. When installing the flowmeters with PTFE lining, flange nuts should not be unsymmetrically tightened to avoid PTER lining deformation.

9. Variable area flowmeters with liquid crystal display should avoid direct sunlight to reduce the life of liquid crystal. Instruments with lithium battery power supply should avoid direct sunlight and high temperature environment (≥65℃)to avoid reducing the capacity and life oflithium battery.