Menu
Your Cart

3 kVA Medical Isolation Transformer, 1 Phase, 120V to 240V

3 kVA Medical Isolation Transformer, 1 Phase, 120V to 240V
3 kVA Medical Isolation Transformer, 1 Phase, 120V to 240V
3 kVA Medical Isolation Transformer, 1 Phase, 120V to 240V
3 kVA Medical Isolation Transformer, 1 Phase, 120V to 240V
3 kVA Medical Isolation Transformer, 1 Phase, 120V to 240V
3 kVA Medical Isolation Transformer, 1 Phase, 120V to 240V
3 kVA Medical Isolation Transformer, 1 Phase, 120V to 240V
  • Stock: In Stock
  • Model: PEACO-IT-3KVA
  • SKU: PEACO-MIT-1S3K
$2,986.00
Ex Tax: $2,986.00

Available Options

Free Shipping Worldwide.
By DHL/ FedEx/ UPS.
Lead Time 7-12 Days.
Mail Us for Lead Time of Custom Products.
MOQ 1.
Buy More Save More.
3 kVA medical isolation transformer comes with single phase, primary voltage & secondary voltage up to 1V-500V and the transformer rated capacity and voltages can be customized. High performance medical grade isolation transformer provides safe, reliable and continuous power distribution for critical equipment in operating rooms, ICU/CCU intensive care units.
Specification
Model PEACO-IT-3KVA
Capacity* 3 kVA (Customized)
Primary Voltage (AC)* 110, 120, 208, 220, 230, 240, 380, 400, 440, 460, 480, 110/220, 120/240, 240/480, 500V (Customized)
Secondary Voltage (AC)* 6, 12, 24, 36, 48, 110, 120, 208, 220, 230, 240, 380, 400, 440, 460, 480, 110/220, 120/240, 240/480, 500V (Customized)
Frequency* 50Hz / 60Hz
Winding Material* Enameled copper wire or enameled aluminum wire (Optional)
Frequency 50Hz / 60Hz Efficiency ≥80%~99%
Insulation Level* F / H grade (Optional) Ground Resistance 25A<100mΩ
Dielectric Withstanding Voltage 2500V AC/min Insulation Resistance ≥500Ω
Overload Capacity Double rated current can last 1 minute Cooling Method Natural cooling
Protection Grade* IP00 (Open type), IP20 (Closed type, customized) Temperature Rise F≤100K, H≤125K
Operating Temperature -15℃~40℃ Noise ≤40dB (A) (within 1 metre)
Altitude ≤2000m Relative Humidity <90%
Designed Life 20 years Working Method Unattended work for long time
Certificate CE Warranty 1 year
Note: * denotes optional and customized parameters and you can select every parameter in drop-down lists to complete your order.
Transformer Features

  • The transformation ratio between the primary winding and the secondary winding is 1:1.
  • The transformer winding is made of H-class enameled copper wire, with a temperature resistance of 180℃. Compact and uniform arrangement, no insulation layer on the surface, with high aesthetic feeling and heat dissipation.
  • Double insulation is adopted between the windings and an electrostatic shielding layer is designed in the electrical isolation transformer.
  • The medical isolation transformer adopts vacuum pressure impregnation of insulating varnish with temperature resistance of 180℃, which has extremely high heat resistance, corrosion resistance, low noise and good insulation performance.
  • The isolation transformer has excellent filtering effect and is used to convert TN system to IT system (ungrounded system).
  • The medical grade isolation transformer has built-in PT100 temperature sensor to monitor its temperature.

Transformer Shell Features

  • Steel plate shell.
  • Protection class is IP20 or can be customized for you.
  • There are cable entry holes.
  • The housing has fixed holes for easy installation and replacement.

The medical isolation transformer is widely used in ventilators, infusion pumps, testing equipment, pulse compressors, patient monitoring equipment, high-frequency enclosure equipment, etc.

Medical Isolation Transformer Schematic Diagram
Medical Isolation Transformer Schematic Diagram
What are the functions of medical isolation transformers?
There are many special equipment in the medical field, many of which are designed to ensure the safety as well as stability of the medical environment in hospitals. Meanwhile, medical isolation transformer is one of those medical equipment, which is very easy-to-use and whose functions are gradually expanding. Especially with the continuous development of current medical equipment, medical isolation transformers play increasingly important role in medical field.
1. Insulation
The main function of high-quality medical isolation transformer is the insulation of electrical appliances. Namely, such a transformer can isolate electrical circuits. Why can the medical transformer insulate so effectively? The reason is that there is an iron core inside the isolation transformer and the high frequency loss of the iron core is relatively large, so that the medical isolation transformer can suppress high-frequency clutter from entering the control loop, thereby reducing the capacitor current. Therefore, the medical isolation transformer can avoid personal injury after limiting the current.
2. Electrical isolation
Many non-professionals only know that medical isolation transformers have the function of electrical insulation. However, as a protection device, the voltage isolation is more critical and necessary. For example, when discharging or power grid conversion occur, the isolation transformer can suppress them by suppressing power supply noise to protect personal safety. Therefore, the probability of electric shock after using an isolation transformer is greatly reduced.
3. Reducing the failure of other parts
In addition to the insulation and electrical isolation above, medical isolation transformers also help decrease the fault of other parts. The medical transformers have certain physical practicability. For example, it does not need to cooperate with a large number of other auxiliary facilities to work and can work independently to avoid the internal environment or other objective factors from damaging the isolation transformer and it will not have relative impact on other equipment and reduce or eliminate other component failures. Therefore, from this point of view, medical isolation transformers have greatly improved safety.
All in all, medical isolation transformers play a very important role in the medical field. Currently, many hospitals require the use of isolation transformers to ensure medical safety.