Menu
Your Cart

5 kVA Isolation Transformer, 3 Phase, 415V to 200V

5 kVA Isolation Transformer, 3 Phase, 415V to 200V
5 kVA Isolation Transformer, 3 Phase, 415V to 200V
5 kVA Isolation Transformer, 3 Phase, 415V to 200V
5 kVA Isolation Transformer, 3 Phase, 415V to 200V
5 kVA Isolation Transformer, 3 Phase, 415V to 200V
5 kVA Isolation Transformer, 3 Phase, 415V to 200V
5 kVA Isolation Transformer, 3 Phase, 415V to 200V
5 kVA Isolation Transformer, 3 Phase, 415V to 200V
Custom
5 kVA Isolation Transformer, 3 Phase, 415V to 200V
5 kVA Isolation Transformer, 3 Phase, 415V to 200V
5 kVA Isolation Transformer, 3 Phase, 415V to 200V
5 kVA Isolation Transformer, 3 Phase, 415V to 200V
5 kVA Isolation Transformer, 3 Phase, 415V to 200V
5 kVA Isolation Transformer, 3 Phase, 415V to 200V
5 kVA Isolation Transformer, 3 Phase, 415V to 200V
5 kVA Isolation Transformer, 3 Phase, 415V to 200V
5 kVA Isolation Transformer, 3 Phase, 415V to 200V
  • Stock: In Stock
  • Model: PEACO-SG-5KVA
  • SKU: PEACO-SG-5KVA
$1,679.57
Ex Tax: $1,679.57

Available Options

Free Shipping Worldwide.
By DHL/ FedEx/ UPS.
Lead Time 7-12 Days.
Mail Us for Lead Time of Custom Products.
MOQ 1.
Buy More Save More.
5 kVA isolation transformer is a 3 phase transformer with electrostatic shields, H-grade 180-degree enameled wires, converting primary voltage 415V to secondary voltage 200V. Optional enameled copper/ aluminum wires, open/ enclosed type, the silicon steel sheet adopts a new square iron core. Dry type isolation transformer with low prices, short lead time. Other voltages of isolation transformer can be customized.

Technical Parameters

  • Model : PEACO-SG-5KVA / SGG-5KVA (two models have different sizes for open type.)
  • Capacity* : 5 kVA (Customized)
  • Frequency : 50Hz/60Hz
  • Primary voltage (VAC)* : 120V/ 190V/ 208V/ 220V/ 230V/ 240V/ 380V/ 400V/ 440V/ 415V/ 460V/ 480V/690V...(Customized)
  • Secondary voltage (VAC)* : 120V/ 190V/ 208V/ 220V/ 230V/ 240V/ 380V/ 400V/ 440V/ 415V/ 460V/ 480V/690V...(Customized)
  • Withstand voltage test : 100% tested. Primary to secondary 2.5kV AC/min; Primary to safety ground 2.5kV AC/min; Secondary to safety ground 2.5kV AC/min. (does not have both puncture and break-down)
  • Insulation resistance : >100MΩ / DC500V
  • Insulation class : B/H
  • Overload capability : 300% for 10 seconds, 150% for 120 seconds
  • Efficiency : ≥ 98%
  • Short circuit impedance : 4%
  • Total Harmonic Distortion : ≤1%
  • Power factor : 0.8
  • Primary to secondary winding isolation voltage : 1000V~3000V
  • Connection mode : standard Dyn11 and customized Ynyn0, Yd11, Dd0. Dyn5. Dzn0, etc, as per customer requriements.
  • Temperature rise limit : 100K (actual temperature minus ambient temperature)
  • Enclosure protection grade : standard IP22 indoor ( contact us for customized electrostatic shield or IP54, IP65 outdoor).
  • Cooling mode : Natural cooling / fan system cooling
  • Display* : Analogue display, digital display.
  • Weight: open type: 50kg-55kg, enclosed type: 60kg-70kg

Transformer Material

  • Material : Transformer coil adopts 200 degree high temperature copper or aluminum wire.
  • Winding material* : 100% copper or aluminum (Optional)

Working Environment

  • Noise : ≤45dB (within 1m)
  • Environment temperature : -20℃~+50℃, indoor enclosure, floor-mounted

Quality Assurance

  • Standard : IEC60076-1, VDE0550, IEC439, JB5555, GB5226, etc.
  • Certification : CE, RoHS and ISO:9001
  • Design Life : 30 years
  • Warranty : 1 year
Note: * denotes optional and customized parameters and you can select every parameter in drop-down lists to complete your order.
Features and Benefits
Isolation transformer is also a 1 to 1 isolation transformer. Peaco Support provides custom isolation transformer with special input and output voltages. For example, 240V to 240V isolation transformer, 480V to 400V step down transformer, 208V to 400V step up transformer, etc can be also customized. The three phase isolation transformers in Peaco Support have the following features and benefits:
  • Silicon Steel Sheet: New cold rolled silicon steel sheet, 0.27mm, 0.30mm, 0.35mm of thickness, excellent performance.
  • Terminal Block: High quality terminal block, excellent temperature resistance, pressure resistance and flame retardancy for small power. For high power, made of quality copper material, with good electrical conductivity, high temperature resistance, not easy to burn out the equipment when short circuit happens.
  • Enameled Wires: H class enamelled copper/aluminum wires, temperature resistance180℃, winded tightly and uniformly, no insulating layer, high heat dissipation, service life ≥35 years.
  • Bobbin: The dry type isolation transformer is made of nylon, high temperature resistance, great flame retardancy. The high power transformer with frameless design has ventilation slots between the coils for smooth air flows which reduce temperature of coils.
  • Insulation Process: The small isolation transformer adopts H-class vacuum impregnated insulation, temperature resistance of 180°C, lower noise, better insulation and is anti-rust and anti-corrosion.
3 Phase Isolation Transformer
Isolation Transformer Dimension (Unit:mm)
Model : PEACO-SG-5KVA
Isolation Transformer Dimension5 kVA Three Phase Isolation Transformer
Model : PEACO-SGG-5KVA
Isolation Transformer Dimension5 kVA Three Phase Isolation Transformer
Isolation Transformer Schematic Diagram
3 Phase Isolation Transformer Schematic Diagram
KNOWLEDGE BASE --- Three Phase Isolating Transformer Principle
The principle of 3 phase isolation transformer is the same as that of ordinary transformer. The electrical isolation transformer is made according to the principle of electromagnetic induction. Isolation transformer generally refers to a 1:1 transformer. Because the secondary is not connected to the ground. There is no potential difference between any secondary line and ground and it is safe to use and used asmaintenance power supply.

Not all isolation transformers are 1:1 transformers. The power supply for the control transformer and electronic tube equipment is also an isolation transformer. Those power supplies such as tube amplifiers, tube radios, oscilloscopes and lathe control transformers are all isolation transformers. For example, a 1:1 isolation transformer is commonly used for safe maintenance of color TVs. Isolation transformers are used more widely and they are also used in air conditioners.

Although the primary and secondary windings of general transformer also can isolate the circuit, the capacitance between the two windings will still cause electrostatic interference between the circuits on both sides in the case of high frequency. In order to avoid this interference, the primary and secondary windings of isolation transformer are generally placed on different core legs to reduce their capacitance. The primary and secondary windings are also placed concentrically, but electrostatic shielding should be placed between the windings to obtain high anti-interference.

How to do the electrostatic shielding? It is to set up an unclosed copper sheet or non-magnetic conductive paper between the primary and secondary windings, which is called a shielding layer. The copper sheet or non-magnetic conductive paper is connected to the shell with a wire. Sometimes a shielding shell is also covered throughout the transformer in order to obtain a better shielding effect. The lead terminal of the winding is also shielded to prevent other external electromagnetic interference. In this way, the main residual magnetic coupling between the primary and secondary windings can be achieved and the equivalent distributed capacitance between them can be less than 0.01pF, thereby greatly reducing the capacitive current between the primary and secondary windings and effectively suppressing various interference from the power supply and other circuits.