Menu
Your Cart

3 Phase Isolation Transformer, 1KVA-10KVA, Enclosed / Open Type

3 Phase Isolation Transformer, 1KVA-10KVA, Enclosed / Open Type
3 Phase Isolation Transformer, 1KVA-10KVA, Enclosed / Open Type
3 Phase Isolation Transformer, 1KVA-10KVA, Enclosed / Open Type
3 Phase Isolation Transformer, 1KVA-10KVA, Enclosed / Open Type
3 Phase Isolation Transformer, 1KVA-10KVA, Enclosed / Open Type
3 Phase Isolation Transformer, 1KVA-10KVA, Enclosed / Open Type
3 Phase Isolation Transformer, 1KVA-10KVA, Enclosed / Open Type
3 Phase Isolation Transformer, 1KVA-10KVA, Enclosed / Open Type
3 Phase Isolation Transformer, 1KVA-10KVA, Enclosed / Open Type
3 Phase Isolation Transformer, 1KVA-10KVA, Enclosed / Open Type
3 Phase Isolation Transformer, 1KVA-10KVA, Enclosed / Open Type
3 Phase Isolation Transformer, 1KVA-10KVA, Enclosed / Open Type
3 Phase Isolation Transformer, 1KVA-10KVA, Enclosed / Open Type
  • Stock: In Stock
  • Model: PSG-1K-10K
  • SKU: PSG-1K-10K
$1,085.56
Ex Tax: $1,085.56

Available Options

Free Shipping Worldwide.
By DHL/ FedEx/ UPS.
Lead Time 7-12 Days.
Mail Us for Lead Time of Custom Products.
MOQ 1.
Buy More Save More.
Peaco Support three phase control transformer comes with a wide range of rated capacity, which can be customized, ranging from 1KVA, 2KVA, 3KVA...to 8KVA, 9KVA, 10KVA. Primary and secondary voltages are also customizable. Enclosed transformer or open type transformer for option. Frequency up to 50Hz and 60Hz. The dry type isolation transformer is widely used to isolate safety and noise especially in industrial factory and laboratory environments where there is a higher power capacity.

Technical Parameters

  • Model : PEACO-SG-750VA/100KVA
  • Capacity* : 750VA ~ 100KVA(Customized)
  • Frequency : 50Hz/60Hz
  • Primary voltage (VAC)* : 120V/ 190V/ 208V/ 220V/ 230V/ 240V/ 380V/ 400V/ 440V/ 415V/ 460V/ 480V/690V...(Customized)
  • Secondary voltage (VAC)* : 120V/ 190V/ 208V/ 220V/ 230V/ 240V/ 380V/ 400V/ 440V/ 415V/ 460V/ 480V/690V...(Customized)
  • Withstand voltage test : 100% tested. Primary to secondary 2.5kV AC/min; Primary to safety ground 2.5kV AC/min; Secondary to safety ground 2.5kV AC/min. (does not have both puncture and break-down)
  • Insulation resistance : >100MΩ / DC500V
  • Insulation class : B/H
  • Overload capability : 300% for 10 seconds, 150% for 120 seconds
  • Efficiency : ≥98%
  • Short circuit impedance : 4%
  • Total Harmonic Distortion : ≤1%
  • Power factor : 0.8
  • Primary to secondary winding isolation voltage : 1000V~3000V
  • Connection mode* : Dyn11 (Delta/Y, Y/Y, Delta/Detal can be also customized)
  • Temperature rise limit : 100K (actual temperature minus ambient temperature)
  • Enclosure protection grade : IP23 indoor, electrostatic shield or IP54, IP65 outdoor for options
  • Cooling mode : Natural cooling / fan system cooling
  • Display* : Analogue display, digital display.

Transformer Material

  • Material*: Transformer coil adopts 200 degree high temperature copper or aluminum wire.
  • Winding material : 100% copper or aluminum (Optional)

Working Environment

  • Noise : ≤45dB (within 1m)
  • Environment temperature : -20℃~+50℃, indoor enclosure, floor-mounted

Quality Assurance

  • Standard : IEC60076-1, VDE0550, IEC439, JB5555, GB5226, etc.
  • Certification : CE, RoHS and ISO:9001
  • Design Life : 30 years
  • Warranty : 2 years
  • After-sales service : within 24 hours
Note:
Features
  • The capacity, input voltage and output voltage can be customized according to your special needs.
  • Enclosed transformer and open type transformer are available for you to choose.
  • Winding is made of enameled copper wire or aluminum wire which can be selected.
  • Insulation class of materials used is Class H.
  • The transformer features natural or air cooling and a suitable clearance around it is required.
  • The 3 phase transformers are designed for 30 years of life and the transformer units come with 2 year warranty.
  • 3 phase isolation transformer comes with CE, RoHS, ISO certificate with guaranteed quality.
  • The three phase isolation transformer is mainly used for industrial, factory and laboratory environments with high current input supply while single phase isolation transformer is for domestic use.
3 Phase Isolation Transformer Dimension (Unit:mm)
3 Phase Isolation Transformer Dimension
Rated Capacity (Optional) Overall size A*B*C Installation Dimension D*E Weight of Aluminium Wire Transformer Weight of Copper Wire Transformer
Open Type Protected Type Open Type Protected Type
1KVA 240*130*255mm 130*90mm 14.0 kg 28 kg 12 kg 29.0 kg
1.5KVA 240*140*255mm 130*100MM 7.0 kg 32.0 kg 15.5 kg 34.0 kg
2KVA 240*155*255mm 130*115mm 20.0 kg 36.0 kg 19.0 kg 37.0 kg
2.5KVA 240*170*250mm 130*130mm 8.5 kg 40.5 kg 23.0 kg 40.5 kg
3KVA 300*140*310mm 180*110mm 30.0 kg 45.0 kg 25.0 kg 44.0 kg
4KVA 300*155*310mm 180*125mm 37.0 kg 55.0c kg 30.0 kg 50.0 kg
5KVA 380*200*380mm 260*110mm 44.0 kg 61.0 kg 43.0 kg 58.0 kg
6KVA 380*200*380mm 260*110mm 46.0 kg 65.0 kg 48.0 kg 68.0 kg
7KVA 380*220*380mm 260*130mm 48.0 kg 70.0 kg 53.0 kg 78.0 kg
8KVA 380*220*380mm 260*130mm 57.0 kg 75.0 kg 59.0 kg 82.0 kg
10KVA 380*240*380mm 260*150mm 65.0 kg 84.0 kg 75.0 kg 100.0 kg
Isolation Transformer Schematic Diagram
3 Phase Isolation Transformer Schematic Diagram

Write a review

Note: HTML is not translated!
Bad Good