25A Capacitor Switching Contactor, 1 NO + 1 NC

25A Capacitor Switching Contactor, 1 NO + 1 NC
25A Capacitor Switching Contactor, 1 NO + 1 NC
25A Capacitor Switching Contactor, 1 NO + 1 NC
25A Capacitor Switching Contactor, 1 NO + 1 NC
25A Capacitor Switching Contactor, 1 NO + 1 NC
  • Stock: In Stock
  • Model: PEACO-CI19-25
  • SKU: PEACO-CI19-25
$89.67
Ex Tax: $89.67

Available Options

Free Shipping Worldwide.
By DHL/ FedEx/ UPS.
Lead Time 7-12 Days.
Mail Us for Lead Time of Custom Products.
MOQ 1.
Buy More Save More.

Capacitor switching contactor can reduce the closing current impact of capacitors, its current is 25A, features optional 2 NO, 1 NO+ 1 NC, 2 NC auxiliary contact composition, high performance AC contactor with silver contacts, low power consumption.

AC Contactor Specifications

Model: PEACO-CI19-25

Poles description: 3P

Controllable capacitor capacity: 6 Kvar (for 220V), 12 Kvar (for 380V)

Rated insulation voltage: 500V

Rated operational voltage: 220V/240V, 380V/400V (Optional)

Conventional thermal current: 25A

Rated working current AC-6b and 400VA: 17A

Prevention capacity on closing surge: 20le

Action condition: pull-in (85%-110%) Us, release (20%-75%) Us

Coil power (start/keep): 70/8 VA

Control supply voltage: 110V, 127V, 220V, 380V

Highest operating frequency (Tme/hour): 120

Electrical life: 100, 000 times

Mechanical life: 1,000,000 times

Auxiliary contact composition: 2 NO (20), 1 NO+ 1 NC (11), 2 NC (02) (Optional)

Auxiliary contact control capacity: AC-15 360VA, DC-13 33W

Weight: 0.44kg

Application

CJ19 series capacitor switching contactors are widely used in power network of AC 50H or 60Hz, voltage up to 380V for operating or switching LV capacitor control device in LV reactive power circuit. The AC contactor is equipped with an inrush current suppressing device, which can effectively reduce the impact of closing surge on the capacitor and suppress the overvoltage when it is off.

Features

1. The AC contactor is equipped with a current-limiting resistor, which can suppress the closing inrush within the allowable range.

2. Capacitor switching contactor features a direct-acting double-breakpoint structure, with flexible action mechanism and compact structure, convenient to check manually and replace contacts.

3. The AC contactor terminals are covered with an insulating cover, which is safe and reliable.

4. The installation can be fastened with screws or it can be fastened on the 35 mm or 75 mm standard installation rail.

Environment

1. Ambient temperature: -5℃~+40℃, the average value should not exceed +35℃ within 24 hours.

2. Altitude: <2000m.

3. Atmospheric conditions: When the temperature reaches 40℃, the relative humidity of atmosphere should be <50%. When at relatively low temperatures, it could have higher relative humidity, such as relative humidity up to 90% at 20℃. Special measures should be taken if there is occurrence of dews due to temperature changes.

4. Class of pollution: Class 3

5. Installation category. Ⅲ

6. Installation conditions: The inclination degree between the installation surface and the vertical surface does not exceed ±5°.

7. Impact shock: AC contactors should be installed and used in the place where there are no strong shakes and impacts.

AC Contactor Wiring Diagram
AC Contactor Wiring Diagram