95 Amp AC Contactor Switch, 3 Pole / 4 Pole, 24V/110V Coil

95 Amp AC Contactor Switch, 3 Pole / 4 Pole, 24V/110V Coil
95 Amp AC Contactor Switch, 3 Pole / 4 Pole, 24V/110V Coil
  • Stock: In Stock
  • Model: PEACO-CJX2-95
  • SKU: PEACO-ACC-10
$257.95
Ex Tax: $257.95

Available Options

Free Shipping Worldwide.
By DHL/ FedEx/ UPS.
Lead Time 7-12 Days.
Mail Us for Lead Time of Custom Products.
MOQ 1.
Buy More Save More.

AC contactor is suitable for long distance breaking circuit and frequently starting or control the motor. the CJX2 series AC contactor comes with optional 80A, 37A, 49A, 17.3A rated current, features 95A/ 44A/ 49A/ 21.3A rated current, a wide selections of contact coils can be chosen, including 24V AC contactor, 110V AC contactor, 220V AC contactor available. AC contactor can be combined with proper thermal overload relay to protect the load circuit.

AC Contactor Specifications

Model PEACO-CJX2-95
Rated current* (optional)
380V AC-3 95A
AC-4 44A
660V AC-3 49A
AC-4 21.3A
Conventional heating current 110A
Rated insulation voltage 690V
Power of controllable 3-phase squirrel cage motor (AC-3) 220V 25kW
380V 45kW
660V 55kW
Operational frequency Electric life AC-3 600 operations/h
AC-4 150 operations/h
Mechanical life 2400 operations/h
Service life Electric life AC-3 600,000 operations
AC-4 100,000 operations
Mechanical life 600,000 operations
Matching fusing model RT16-125
Average power consumption at 50Hz, 20℃ Pick-up 230VA
Holding 32VA
Pole* (Optional) 3P+NO, 3P+NC
Weight 1.42kg-1.65kg
Certification CCC
Warranty 2 years

Note: For electricity-related maintenance and installation, make sure that the operator holds the qualification for electrical work and takes necessary power-off and insulation protection measures.

Features

  • 32 pieces of iron core with solid materials, the suction is more smooth and tight.
  • Provides silver alloy contacts with strong conductivity and flame retardant housing.
  • With copper coils with strong electromagnetic suction when the coil is energized.

Normal Working and Installation Conditions

1. Ambient temperature: -5℃~+40℃, the average value should not exceed +35℃ within 24 hours.

2. Altitude: <2000m.

3. Atmospheric conditions: When the temperature reaches 40℃, the relative humidity of atmosphere should be <50%. When at relatively low temperatures, it could have higher relative humidity. Monthly maximum relative humidity could be not more than 90%. Special measures should be taken if there is occurrence of dews due to temperature changes.

4. Class of pollution: Class 3

5. Installation category. Ⅲ

6. Installation conditions: The inclination degree between the installation surface and the vertical surface does not exceed ±5°.

7. Impact shock: AC contactors should be installed and used in the place where there are no strong shakes and impacts.

AC Contactor Dimension (Unit: mm)

AC Contactor Dimension

Amax=87, Bmax=129, Cmax=127, Dmax=155, Emax=175, Fmax=113, a=40, b=100/110, Φ=6.5

AC Contactor Details (Taking CJX2-0910 AC contactor as an example.)
AC Contactor Details
AC Contactor Wiring Diagram (Taking 220V AC coil voltage as an example.)
AC Contactor Wiring Diagram