Menu
Your Cart

100 Amps High Voltage DC Contactor, 12V/24V Coil

100 Amps High Voltage DC Contactor, 12V/24V Coil
100 Amps High Voltage DC Contactor, 12V/24V Coil
100 Amps High Voltage DC Contactor, 12V/24V Coil
100 Amps High Voltage DC Contactor, 12V/24V Coil
100 Amps High Voltage DC Contactor, 12V/24V Coil
100 Amps High Voltage DC Contactor, 12V/24V Coil
100 Amps High Voltage DC Contactor, 12V/24V Coil
100 Amps High Voltage DC Contactor, 12V/24V Coil
100 Amps High Voltage DC Contactor, 12V/24V Coil
100 Amps High Voltage DC Contactor, 12V/24V Coil
100 Amps High Voltage DC Contactor, 12V/24V Coil
  • Stock: In Stock
  • Model: PEACO-ADH100
  • SKU: PEACO-ADH100
$135.47
Ex Tax: $135.47

Available Options

Free Shipping Worldwide.
By DHL/ FedEx/ UPS.
Lead Time 7-12 Days.
Mail Us for Lead Time of Custom Products.
MOQ 1.
Buy More Save More.

Peaco Support high voltage 100A dc contactor is equipped with 12~1000V DC rated load voltage,12V DC contactor and 24V DC contactor is normally open (SPST-NO) type, 12V or 24V coils for selection, optional built-in energy-saving coil. High quality with RoHS, CE certification, high performance, high reliable and low cost.

For more DC contactors and datasheet, please visit here Peaco Support DC contactor catalogue.pdf.

Features

  • Optional coil voltage: 12 Volt DC contactor and 24 Volt DC contactor.
  • Epoxy sealed. Epoxy resin encapsulated seal structure allows the working in explosive and harmful environment and coils and contacts will not be oxidized and polluted.
  • High efficiency coil. Optional built-in energy-saving coil. The energy-saving coil holds 2~2.3W power, counter electromotive force up to 0V.
  • Non-polarity. There is no polarity requirement for contacts and coil connections.
  • No electromagnetic counter force. The joint way of the coil is convenient.
  • Compact design, low noise. Optional standard type and energy saving type high voltage DC contactor.
  • Meet CCC, RoHS, CE and ISO9001 conformance requirements.

Applications: Peaco Support high voltage DC contactors are used in electric control systems such as automotive electric winches, telecommunication equipment, construction machinery, battery trucks, electric forklifts, trains, ships, uninterrupted power supplies, etc.

Specifications

Basic Specification Model PEACO-ADH100-S PEACO-ADH100-E
Weight 230g 220g
Dimension 55*42*62mm 55*50*62mm
Certification CCC, RoHS, CE and ISO9001
Application Continuous
Contact Specification Contact Arrangement SPST-1NO Contact
Auxiliary Contact (Optional)*
1-NO
Contact Resistance ≤30mΩ (@6V DC 20A)
Rated Load Voltage 12~1000VDC
Electrical Endurance (Resistance) 10,000 times (100A 750V DC)
Maximum Switching Power / Current 320 kW / 1000A 320VDC (>1 time)
Protection Grade IP67
Rated Load Current 100A
Mechanical Life 1,000,000 times
Min. Load 1A 12VDC
Standard Continuous (Carry) Current (40mm2 Leads) 100A
Short Time Overload Current (40mm2 at 40℃) 150A 15min, 200A 3min, 300A 30s
Load Terminal and Center Distance M5 Internal Thread, 18mm
Coil Specification Coil Type Standard Type Voltage Energy Saving Type Voltage
Standard Type Voltage 12VDC 24VDC 12V/24V DC
Working Voltage 9-16V 8-32V 8-36V
Max. Voltage 16V 32V 36V
Action Voltage ≤9V ≤18V 7-8V
Release Voltage ≥1V ≥2V 5-6V
Coil Resistance±10% 26Ω 96Ω 4.7Ω
Min Start Current 0.46A 0.25A 1.5A
Transient Inrush Current / / 2.5A (0.1s)
Average Holding Current 0.46A 0.25A 0.18A (@ 12V)
Steady State Power 5.5W 6.0W 2.0-2.3W
Actuation Times ≤25ms ≤25ms ≤20ms
Release Times, Bounce Times ≤10ms, ≤ 5ms ≤10ms, ≤ 5ms ≤10ms, ≤ 5ms

Note:
1. Auxiliary Contact Form: 1-NO (Normally Open Auxiliary Contact).
2. The parameters above are the initial values measured at 23℃. Other coil rated voltages can be customized.
Electrical Specification
  • Insulation Resistance: 1000MΩ (500VDC) between contacts, between coil and contacts and between shell and contacts.
  • Dielectric Withstanding Voltage: 2500VAC,1ms Between Coil and Contacts and 8000VAC, 1ms between contacts.
Mechanical Specification
  • Impact: 196m/s2 (6 ms) stability and 490m/s2 (6 ms) strength.
  • Vibration: Sine 80Hz~2000Hz (20G Max.)
  • IP Grade: IP67
Life Expectancy
  • Mechanical Life: 1,000,000 times
  • Electrical Endurance (Resistance): 10,000 times (100A 750VDC)
Usage Conditions
  • Humidity: 5~95% RH
  • Temperature: -40℃~85℃

100A DC Contactor Dimensions (unit=mm)

DC Contactor Dimension

Notes: 12V dc coil contactor and 24v dc coil contactor sizes are noted without dimensional tolerance. So, consider the tolerance of ±0.3 mm for dimensions less than 10mm, ±0.5 mm for dimensions 10-50mm and ±0.8 mm for dimensions more than 50 mm.
High Voltage DC Contactor Schematic Diagram
DC Contactor Connection Diagram
Notes:
  • Resistive load includes the maximum inductance up to 300 uH.
  • It is recommended to do test for different situations according to the extrapolation.
  • Dielectric strength drops to lower than 100mΩ at 1000VDC after life time.