Menu
Your Cart

40 hp Variable Frequency Drive, Single Phase to 3 Phase VFD

40 hp Variable Frequency Drive, Single Phase to 3 Phase VFD
40 hp Variable Frequency Drive, Single Phase to 3 Phase VFD
40 hp Variable Frequency Drive, Single Phase to 3 Phase VFD
40 hp Variable Frequency Drive, Single Phase to 3 Phase VFD
40 hp Variable Frequency Drive, Single Phase to 3 Phase VFD
  • Stock: In Stock
  • Model: PEACO-FC280-2S/4T-30G/37.5P
  • SKU: PEACO-STVFD-40
$2,554.59
Ex Tax: $2,554.59

Available Options

Free Shipping Worldwide.
By DHL/ FedEx/ UPS.
Lead Time 7-12 Days.
Mail Us for Lead Time of Custom Products.
MOQ 1.
Buy More Save More.

40 hp variable frequency drive converts single phase 220V, 230V, 240V input to three phase 220V, 380V, 400V, 480V, 690V output, 61A rated output current, is an energy efficient pump control drive with high performance. Cost-effective 40 hp VFD is widely used to control the speed of AC induction motors.

Our VFD are suitable for single phase and split phase input power supply.

For the 40 hp VFD user manual, please contact us.

Navigation: Motor Controls > Variable Frequency Drives >1 Phase to 3 Phase VFD > 40 hp Variable Frequency Drive, Single Phase to 3 Phase VFD

Specifications

Basics Model PEACO-FC280-2S/4T-30G/37.5P
Rated Capacity 40 hp (30 kW)
Rated Input Current 196A (for 220V)
Rated Output Current 60A (for 380V)
Certification CE
Warranty 12 months
Applicable Motor Output30 kW
Power Input Rated Voltage*220V±10%
Output Rated Voltage* 220V±10%, 380V±10%
Rated Frequency 1.0~3200Hz
Robust Design IGBT current > 2 times of inverter output current, Capacitor > 50uF/A
PCB aging test 100% test, 50°C, 12 hours.
Finished products aging test 100% test, 50°C, 24 hours.
Control Feature Control System VF Control / Open Sensor Vector Control / Closed loop Vector (PG card - for lift/elevator)
Output Frequency Resolution 0.1Hz
Torque Characteristics Including the auto-torque, auto-slip compensation, starting torque can be 0.5 Hz/150% (V/f), 1 Hz/150% (SVC),0 Hz/180% (FVC)
Overload Endurance 150% / 120s, 160% / 60s, 180% / 10s, 200% / 1s
Accel / Decel Time 0.1~65000s. (can be set individually)
Torque Boost Automatically torque boost, manually torque boost: 0.1%~30.0%
Stall Prevention Level 20~200%, setting of Rated Current
Operating Feature Input / Output Terminals Keypad Removable
Input terminals 6 multifunctional inputs, one can be work as high speed pulse Input.
3 programmable analog input: AI1, AI2, AI3: 0~10V / 4~20mA.
Output terminals 2 Groups relay outputs, 1 open collector outputs.
2 Analog outputs, 0~10V / 4~20mA.
Communication Terminals Build-in standard RS485 communication interface. MODBUS-RTU communication protocol.
Built-in PID Built-in PID control to easily realize the close loop control of the process parameters (such as pressure, temperature, flow, etc.)
Jog Operation Jog operation frequency: 0.0Hz~maximum frequency. Jog acceleration/deceleration time: 0.1s~3600.0s.
Other Function AVR, S-curve, Over-Voltage Stall Prevention, DC Braking, Fault Records, Adjustable Carried Frequency, Starting Frequency Setting of DC Braking, Over-Current Stall Prevention, Momentary Power Loss Restart, Reverse Inhibition, Frequency Limits, Parameter Lock/Reset.
Protection Over Voltage, Over Current, Under Voltage, Overload, Electronic thermal, Overheating, Self-testing.
Others Including EMC Filter (C2/C3 Standard)
Cooling Forced air-cooling
Installation Location Altitude 1,000 m or below, keep from corrosive gasses, liquid and dust.
Ambient Temperature -10°C~+40°C (Non-Condensing and not frozen)
Storage Temperature -20°C~+60°C
Ambient Humidity Below 90% RH (non-condensing)
Vibration 9.80665m/s2 (1G) less than 20Hz, 5.88m/s2 (0.6Gat) 20 to 50Hz
External Accessories*
Matched optional input EMC filter, output EMC filter, input AC reactor, output AC reactor, energy regenerated reactor, harmonic filter, sine wave filter (excluding VFD price).
Note:

1. * denotes the parameters are optional or customized and please select every parameter in drop-down lists to complete your order.

2. Please contact us for external accessories catalogue and price.

40 hp VFD Dimension (Unit: mm)

40 hp VFD Dimension

A H D W B Φ Weight
220 411 238 160 395 Φ7 6.5kg

KNOWLEDGE BASE

What is the effect of carrier frequency on VFD?

The carrier frequency has an impact on VFD output current.

1. the higher the operating frequency is, the greater the duty cycle of the voltage wave is, the smaller the high harmonic component of the current is. With the higher carrier frequency, the current waveform is smoother.

2. With the higher carrier frequency, the allowable output current of VFD is smaller.

3. If the carrier frequency is higher, the capacitive reactance of the wiring capacitor will be smaller, because Xc=1/2πfC, and the leakage current caused by the high frequency pulse will be larger.

Need more information for VFD ?

 Peaco Support VFD User Manual


Write a review

Note: HTML is not translated!
Bad Good
Captcha