2 kVA Control Transformer, 1 Phase, 240V/480V to 120V

2 kVA Control Transformer, 1 Phase, 240V/480V to 120V
2 kVA Control Transformer, 1 Phase, 240V/480V to 120V
2 kVA Control Transformer, 1 Phase, 240V/480V to 120V
2 kVA Control Transformer, 1 Phase, 240V/480V to 120V
2 kVA Control Transformer, 1 Phase, 240V/480V to 120V
2 kVA Control Transformer, 1 Phase, 240V/480V to 120V
2 kVA Control Transformer, 1 Phase, 240V/480V to 120V
Custom
2 kVA Control Transformer, 1 Phase, 240V/480V to 120V
2 kVA Control Transformer, 1 Phase, 240V/480V to 120V
2 kVA Control Transformer, 1 Phase, 240V/480V to 120V
2 kVA Control Transformer, 1 Phase, 240V/480V to 120V
2 kVA Control Transformer, 1 Phase, 240V/480V to 120V
2 kVA Control Transformer, 1 Phase, 240V/480V to 120V
2 kVA Control Transformer, 1 Phase, 240V/480V to 120V
2 kVA Control Transformer, 1 Phase, 240V/480V to 120V
  • Stock: In Stock
  • Model: PBK-2kVA
  • SKU: PBK-2kVA
$778.97
Ex Tax: $778.97

Available Options

Free Shipping Worldwide.
By DHL/ FedEx/ UPS.
Lead Time 7-12 Days.
Mail Us for Lead Time of Custom Products.
MOQ 1.
Buy More Save More.
Brand-new 2 kVA control transformer with cheap price from PEACO SUPPORT, can step down 240/480 volt input voltage to output 120 volt, optional enameled copper/ aluminum wires, vacuum impregnated insulation, H insulation level. Reliable transformer for cotrolling voltages in industrial field.
Specification
Model PBK-2kVA
Winding Material* Enameled copper wire or enameled aluminum wire (Optional)
Capacity* 2000VA (Customized)
Primary Voltage (VAC)* 110, 120, 208, 220, 230, 240, 380, 400, 440, 460, 480, 110/220, 120/240, 240/480, 600...(Customized)
Secondary Voltage (VAC)* 6, 12, 24, 36, 48, 110/48, 120/24, 208/36, 220/48, 230/36, 240/120, 120/24/12, 110/36/24, 127/36/6, 208/48/36/24...(Customized)
Withstand Voltage Test Primary to secondary 2.5KV/min; Primary to safety ground 2.5KV/min; Secondary to safety ground 1.5KV/min.
Insulation Resistance Primary to secondary 2500V>100 megohm; Primary to safety ground 2500V>100 megohm; Secondary to safety ground 1500V>100 megohm.
Frequency* 50 / 60Hz Insulation Level F / H
Induction Withstand Voltage Test 125Hz/ 800V/min Ground Resistance 25<A80 milliohm
Cooling Method Natural or air cooling Transformation Ratio <3%
Air Carrying Current <6% Impedance Voltage About 6%
Total Losses / Efficiency 0.1 / 80%~99% Operating Temperature -25℃~40℃ (40℃, 93% RH, 56 days)
Noise ≤35~65dB (A)(within 1 metre) Storage Temperature -25℃~100℃ (40℃, 93% RH, 56 days)
Certificate CE, ISO Designed Life 30 years
Warranty 1 year Net Weight 16.0 kg
Overall Size (A*B*C) 180*160*210mm Installation Dimension (D*E) 130*120mm
Note: * denotes optional and customized parameters and you can select every parameter in drop-down lists to complete your order.
Control Transformer Features
  • Terminal Block: High quality terminal block, excellent temperature resistance, pressure resistance and flame retardancy.
  • Silicon Steel Sheet: New cold rolled silicon steel sheet, 0.27mm, 0.30mm, 0.35mm, excellent performance.
  • Enameled Wires: H class, temperature resistance180℃, winded tightly and uniformly, no insulating layer, high heat dissipation, service life ≥35 years.
  • Bobbin: Made of nylon, high temperature resistance, great flame retardancy, has ventilation slots between the coils for smooth air flows and reducing temperature of coils.
  • Insulation Process: Vacuum impregnated insulation, temperature resistance of 180°C, lower noise, better insulation and is anti-rust and anti-corrosion.

The single phase control transformers are widely used in CNC machine tools and mechanical equipment, working lighting and signal lamp power supplies and can also be used as small power supplies.

Single Phase Control Transformer Features
Control Transformer Dimension & Schematic Diagram
Control Transformer DimensionControl Transformer Schematic Diagram
KNOWLEDGE BASE --- Normal Service Condition Requirements for Control Transformer
  • Insulation resistance
The insulation resistance of the control transformer in the cold state should be no less than 10 MΩ and in the hot state and the wet state it should be no less than 2 MΩ.
  • Insulation strength
The electrical insulation strength of the control transformer should be able to withstand the voltage test of AC 50Hz, 2000V sinusoidal AC voltage and such phenomenon breakdown or flashover will not occur within 1 min.
  • Leakage current
The leakage current of the control transformer must not exceed 3mA.
  • Temperature rise
The limit temperature rise of the control transformer windings (E Class insulation) shall not exceed 75K (resistance method). The limit temperature rise of the iron core (E Class insulation) shall not exceed 55K (semiconductor point thermometer method).
  • Ground
The control transformer shall have a dedicated terminal for grounding and shall be marked with a grounding symbol.